EX3200 switches and EX4200 standalone switches—Replace
slot
with 0.
•
EX4200 switches in a Virtual Chassis configuration—Replace
slot
with a value
from 0 through 9 (switch’s member ID).
•
EX8208 switches—Replace
slot
with a value from 0 through 7 (line card).
•
EX8216 switches—Replace
slot
with a value from 0 through 15 (line card).
Required Privilege
Level
view
List of Sample Output
show chassis environment fpc (M120 Router) on page 768
show chassis environment fpc (M160 Router) on page 769
show chassis environment fpc (M320 Router) on page 769
show chassis environment fpc (MX240 Router) on page 770
show chassis environment fpc (MX480 Router) on page 771
show chassis environment fpc (MX960 Router) on page 772
show chassis environment fpc (T Series Core Routers) on page 773
show chassis environment fpc lcc (TX Matrix Router) on page 773
show chassis environment fpc lcc (TX Matrix Plus Router) on page 774
Output Fields
Table 131 on page 767 lists the output fields for the
show chassis environment fpc
command. Output fields are listed in the approximate order in which they appear.
Table 131: show chassis environment fpc Output Fields
Field Description
Field Name
Status of the FPC:
•
Unknown
—FPC is not detected by the router.
•
Empty
—No FPC is present.
•
Present
—FPC is detected by the chassis daemon but is either not supported by the current version
of the Junos OS, or the FPC is coming up but not yet online.
•
Ready
—FPC is in intermediate or transition state.
•
Announce online
—Intermediate state during which the FPC is coming up but not yet online, and
the chassis manager acknowledges the chassisd FPC online initiative.
•
Online
—FPC is online and running.
•
Offline
—FPC is powered down.
•
Diagnostics
—FPC is set to operate in diagnostics mode.
State
(M40e and M160 routers only) Temperature of the air flowing past the FPC.
Temperature
(M320 routers only) Temperature of the air flowing into the chassis.
Temperature Intake
(T Series routers only) Temperature of the air flowing past the top of the FPC.
Temperature Top
(M120 and M320 routers only) Temperature of the air flowing out of the chassis.
Temperature Exhaust
(T Series routers only) Temperature of the air flowing past the bottom of the FPC.
Temperature Bottom
767
Copyright © 2010, Juniper Networks, Inc.
Chapter 42: Operational Mode Commands for System Monitoring
Summary of Contents for JUNOS OS 10.3 - SOFTWARE
Page 325: ...CHAPTER 17 Operational Mode Commands for System Setup 229 Copyright 2010 Juniper Networks Inc ...
Page 1323: ...CHAPTER 56 Operational Mode Commands for Interfaces 1227 Copyright 2010 Juniper Networks Inc ...
Page 2841: ...CHAPTER 86 Operational Commands for 802 1X 2745 Copyright 2010 Juniper Networks Inc ...
Page 3367: ...CHAPTER 113 Operational Mode Commands for CoS 3271 Copyright 2010 Juniper Networks Inc ...
Page 3435: ...CHAPTER 120 Operational Mode Commands for PoE 3339 Copyright 2010 Juniper Networks Inc ...
Page 3529: ...CHAPTER 126 Operational Mode Commands for MPLS 3433 Copyright 2010 Juniper Networks Inc ...