CHAPTER 2
LTE Mini-PIM Installation and Configuration
IN THIS CHAPTER
Installing the LTE Mini-PIM in a SRX Series Services Gateway | 9
Configuring the LTE Mini-PIM on SRX Series Devices | 14
Installing the LTE Mini-PIM in a SRX Series Services Gateway
To install the LTE Mini-PIM in a services gateway:
NOTE:
You can install only one Mini-PIM in a services gateway. The Mini-PIM can be installed
in any of the Mini-PIM slots on the services gateway.
1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to
the grounding point on the back of the services gateway.
2. Power off the services gateway by briefly pressing the Power button on the front panel. Wait for the
Power LED to turn off before proceeding. Disconnect the services gateway from the power source.
3. Remove the blank Mini-PIM installed on the services gateway:
a. Loosen the screws on the faceplate of the blank Mini-PIM.
b. Grasp the screws on each side and remove the blank Mini-PIM.
4. Remove the LTE Mini-PIM from the electrostatic bag.
5. Grasp the screws on each side of the Mini-PIM faceplate and align the notches in the connector at the
rear of the Mini-PIM with the notches in the Mini-PIM slot in the services gateway.
CAUTION:
Slide the Mini-PIM straight into the slot to avoid damaging the
components on the Mini-PIM.
9