To install a JNP10K-PWR-AC2 power supply in an MX10008 or an MX10016:
1. Attach the electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to
the ESD point on the chassis. There is an ESD point located next to the protective earthing terminal
and below PSU5 on the MX10008 rear panel (see
) or below PSU9 on the
MX10016 (see
Figure 104: ESD Point on the MX10008 Chassis Rear
g100611
1
1
—
ESD point
Figure 105: ESD Point on MX10016 Chassis Rear
g100612
1
1
—
ESD point
2. If the power supply slot has a cover panel on it, insert your thumb and forefinger into the finger holes,
squeeze, and pull the cover out of the slot. Save the cover panel for later use. See
for removal on a MX10008 and
for the MX10016.
210
Summary of Contents for MX10008
Page 1: ...MX10008 Universal Routing Platform Hardware Guide Published 2019 11 11 ...
Page 19: ......
Page 89: ......
Page 129: ......
Page 170: ......
Page 278: ...5 CHAPTER Troubleshooting Hardware Restoring Junos OS 283 Alarm Messages 287 ...
Page 279: ......
Page 287: ......
Page 318: ...Restricted Access Warning 321 ...
Page 333: ...Jewelry Removal Warning 336 ...
Page 336: ...Operating Temperature Warning 339 ...
Page 345: ...DC Power Disconnection Warning 348 ...
Page 349: ...DC Power Wiring Sequence Warning 352 ...
Page 352: ...DC Power Wiring Terminations Warning 355 ...
Page 361: ...Translation The emitted sound pressure is below 92 dB A per GR63 CORE 364 ...