NOTE:
Each battery return of the DC power supply must be connected as an isolated DC return
(DC-I).
•
Ensure you understand how to prevent ESD damage. See
“Prevention of Electrostatic Discharge Damage”
.
•
Ensure that you have the following parts and tools available to install a JNP10K-PWR-DC power supply:
•
Electrostatic discharge (ESD) grounding strap
•
DC power source cables (not provided) with the cable lugs (provided) attached
The provided terminal lugs in an MX10000 are sized for either4 AWG (21.1 mm
2
) or 6 AWG (13.3
mm
2
) power source cables. When running all JNP10K-PWR-DC power supply modules in the chassis,
the DC power source cables that you provide must be 6 AWG (13.3
2
) mm²) stranded wire We
recommend that you install heat-shrink tubing insulation around the crimped section of the power
cables and lugs.
NOTE:
If you upgrade the JNP10K-PWR-DC to a JNP10K-PWR-DC2 and set the input mode
to high (80-A), you must use 4 AWG (21.1 mm²) stranded wire.
NOTE:
See the heat symbol
. Wear heat-resistant gloves while accessing the fan
tray and power supply.
•
13/32 in. (10 mm) nut driver or socket wrench
•
Phillips (+) screwdrivers, numbers 1 and 2
•
Multimeter
To install a JNP10K-PWR-DC power supply in an MX10000:
221
Summary of Contents for MX10008
Page 1: ...MX10008 Universal Routing Platform Hardware Guide Published 2019 11 11 ...
Page 19: ......
Page 89: ......
Page 129: ......
Page 170: ......
Page 278: ...5 CHAPTER Troubleshooting Hardware Restoring Junos OS 283 Alarm Messages 287 ...
Page 279: ......
Page 287: ......
Page 318: ...Restricted Access Warning 321 ...
Page 333: ...Jewelry Removal Warning 336 ...
Page 336: ...Operating Temperature Warning 339 ...
Page 345: ...DC Power Disconnection Warning 348 ...
Page 349: ...DC Power Wiring Sequence Warning 352 ...
Page 352: ...DC Power Wiring Terminations Warning 355 ...
Page 361: ...Translation The emitted sound pressure is below 92 dB A per GR63 CORE 364 ...