CAUTION:
Before you connect power to the router, a licensed electrician must attach
a cable lug to the grounding and power cables that you supply. A cable with an incorrectly
attached lug can damage the router (for example, by causing a short circuit).
CAUTION:
Do not mix AC, DC, or HVDC power supplies in the same running chassis.
You can mix DC and HVDC power supplies while swapping out one type for another
during installation.
CAUTION:
To meet safety and electromagnetic interference (EMI) requirements and to
ensure proper operation, you must connect MX10008 routers to earth ground before
you connect them to power. For installations that require a separate grounding conductor
to the chassis, use the protective earthing terminal on the router chassis to connect to
earth ground. For instructions on connecting an MX10000 router to ground using a
separate grounding conductor, see
“Connecting an MX10000 to Earth Ground” on page 160
NOTE:
The battery returns of the JNP10K-PWR-DC2 power supply must be connected as an
isolated DC return (DC-I).
•
Ensure you understand how to prevent ESD damage. See
“Prevention of Electrostatic Discharge Damage”
.
•
Ensure that you have the following parts and tools available to install a DC power supply:
•
Electrostatic discharge (ESD) grounding strap
•
Use high current cable assembly, CBL-PWR2-BARE (not provided) with the cable lugs (provided)
attached
The provided terminal lugs for the JNP10K-PWR-DC2 are Panduit LCD4-14A-L, or equivalent, and
sized for 4 AWG (21.1 mm
2
) power source cables. We recommend that you install heat-shrink tubing
insulation around the crimped section of the power cables and lugs.
•
13/32 in. (10 mm) nut driver or socket wrench
•
Phillips (+) screwdrivers, numbers 1 and 2
•
Multimeter
To install a JNP10K-PWR-DC2 power supply in an MX10008 or PMTX10016 :
235
Summary of Contents for MX10008
Page 1: ...MX10008 Universal Routing Platform Hardware Guide Published 2019 11 11 ...
Page 19: ......
Page 89: ......
Page 129: ......
Page 170: ......
Page 278: ...5 CHAPTER Troubleshooting Hardware Restoring Junos OS 283 Alarm Messages 287 ...
Page 279: ......
Page 287: ......
Page 318: ...Restricted Access Warning 321 ...
Page 333: ...Jewelry Removal Warning 336 ...
Page 336: ...Operating Temperature Warning 339 ...
Page 345: ...DC Power Disconnection Warning 348 ...
Page 349: ...DC Power Wiring Sequence Warning 352 ...
Page 352: ...DC Power Wiring Terminations Warning 355 ...
Page 361: ...Translation The emitted sound pressure is below 92 dB A per GR63 CORE 364 ...