4. Orient the MPC so that the faceplate is toward you.
5. Lift the MPC into place, and carefully align the sides of the MPC with the guides inside the card cage.
CAUTION:
When the MPC is out of the chassis, do not hold it by the ejector handles,
bus bars, or edge connectors. They cannot support the weight of the MPC.
6. Slide the MPC all the way into the card cage until you feel resistance.
7. Grasp both ejector handles, and simultaneously rotate them clockwise until the MPC is fully seated.
8. Insert the appropriate cable into the cable connector ports on the MPC. Secure the cables so that they
do not support their own weight.
Place any excess cable out of the way in a neatly coiled loop, using the cable management system.
Placing fasteners on a loop helps to maintain the shape of the loop.
CAUTION:
Do not let fiber-optic cables hang free from the connector. Do not allow
the fastened loops of a cable to dangle, which stresses the cable at the fastening point.
CAUTION:
Avoid bending a fiber-optic cable beyond its minimum bend radius. An
arc smaller than a few inches in diameter can damage the cable and cause problems
that are difficult to diagnose.
You can also verify that the MPC is functioning correctly by using the show chassis fpc and show chassis fpc
pic-status commands.
260
Summary of Contents for MX10008
Page 1: ...MX10008 Universal Routing Platform Hardware Guide Published 2019 11 11 ...
Page 19: ......
Page 89: ......
Page 129: ......
Page 170: ......
Page 278: ...5 CHAPTER Troubleshooting Hardware Restoring Junos OS 283 Alarm Messages 287 ...
Page 279: ......
Page 287: ......
Page 318: ...Restricted Access Warning 321 ...
Page 333: ...Jewelry Removal Warning 336 ...
Page 336: ...Operating Temperature Warning 339 ...
Page 345: ...DC Power Disconnection Warning 348 ...
Page 349: ...DC Power Wiring Sequence Warning 352 ...
Page 352: ...DC Power Wiring Terminations Warning 355 ...
Page 361: ...Translation The emitted sound pressure is below 92 dB A per GR63 CORE 364 ...