Fan Tray 1 Fan 19 OK 7800 Spinning at normal speed
Fan Tray 1 Fan 20 OK 6450 Spinning at normal speed
Fan Tray 1 Fan 21 OK 7650 Spinning at normal speed
user@host>
Two fan tray controller models and their associated fan trays are available. See
.
Table 10: Fan Tray Controller Specifications
JNP10008-FTC2
JNP10008-FAN-CTRL
Specification
JNP10008-FAN2
JNP10008-FAN
Corresponding fan tray model
Enhanced or standard
Enhanced or standard
Chassis supported
19.2R1
15.1X53-D30
Introduced in Junos OS Release
1.5 in. (3.81 cm)
1.5 in. (3.81 cm)
Height
6.5 in. (15.24 cm)
6.5 in. (15.24 cm)
Width
9.4 in. (23.88 cm)
9.3 in. (23.62 cm)
Depth
1.1 lb (0.5 kg)
1.5 lb (0.68 kg)
Weight
Airflow Direction in the MX10008 Router
The air intake to cool the chassis is located on the port (line card) side of the chassis. Air flows into the
chassis from the ports in the RCBs and line cards, through the switch fabric boards (SFBs), and exits from
the fan trays and the power supplies. This airflow is called port-to-FRU cooling or airflow out (AFO). See
51
Summary of Contents for MX10008
Page 1: ...MX10008 Universal Routing Platform Hardware Guide Published 2019 11 11 ...
Page 19: ......
Page 89: ......
Page 129: ......
Page 170: ......
Page 278: ...5 CHAPTER Troubleshooting Hardware Restoring Junos OS 283 Alarm Messages 287 ...
Page 279: ......
Page 287: ......
Page 318: ...Restricted Access Warning 321 ...
Page 333: ...Jewelry Removal Warning 336 ...
Page 336: ...Operating Temperature Warning 339 ...
Page 345: ...DC Power Disconnection Warning 348 ...
Page 349: ...DC Power Wiring Sequence Warning 352 ...
Page 352: ...DC Power Wiring Terminations Warning 355 ...
Page 361: ...Translation The emitted sound pressure is below 92 dB A per GR63 CORE 364 ...