Table 32: Line Card Power Consumption (continued)
MX10K-LC2101 (400 Gigabit
Ethernet mode @104° F (40°
C))
MX10K-LC2101 (240 Gigabit
Ethernet mode @104° F (40°
C))
Number of Line Cards
5700 W
4700 W
4
7125 W
5875 W
5
8550 W
7050 W
6
9975 W
8225 W
7
11400 W
9400 W
8
For example, for an MX10008 with eight MX10K-LC2101 line cards, the maximum power consumption
@400 Gigabit Ethernet mode is:
= 8* 1425 W= 11400 W
3. Add the power consumption from Step
and the total line card consumption from Step
.
To continue from the previous example, add the wattage from eight cards to a redundant configuration.
(11400 W) + (2650 W)
= 14050 W required
Calculating the Number of Power Supplies Required for Your MX10008 Configuration
Use this procedure to calculate the number of power supplies required by your router configuration. The
minimum power configuration for MX10008 routers is three power supplies.
To calculate the number of power supplies required for your minimum router configuration:
1. Determine the power available from the power supplies.
shows the power available
for installed power supplies.
Table 33: Total Power Available
With Five Power
Supplies
With Four
Power Supplies
With Three
Power Supplies
Power Supply Module Models
13,500 W
10,800 W
8100 W
JNP10K-PWR-AC
102
Summary of Contents for MX10008
Page 1: ...MX10008 Universal Routing Platform Hardware Guide Published 2019 11 11 ...
Page 19: ......
Page 89: ......
Page 129: ......
Page 170: ......
Page 278: ...5 CHAPTER Troubleshooting Hardware Restoring Junos OS 283 Alarm Messages 287 ...
Page 279: ......
Page 287: ......
Page 318: ...Restricted Access Warning 321 ...
Page 333: ...Jewelry Removal Warning 336 ...
Page 336: ...Operating Temperature Warning 339 ...
Page 345: ...DC Power Disconnection Warning 348 ...
Page 349: ...DC Power Wiring Sequence Warning 352 ...
Page 352: ...DC Power Wiring Terminations Warning 355 ...
Page 361: ...Translation The emitted sound pressure is below 92 dB A per GR63 CORE 364 ...