Figure 140: Proper Load Balancing for JNP10K-PWR-DC2 Power Cables on MX100016
g100690
WARNING:
Ensure that the power cords do not block access to router components
or drape where people can trip on them.
18. Set the three dip switches to set the inputs and whether the power supply is running at 3000 W,
5000 W, or 5500 W. See
and
Set both enable routers to the on position when using both source inputs. When not using source
redundancy, set the unused source to the O (off) position. The LED turns red and indicates an error if
a source input is not in use and the enable router is | (on).
Table 58: Setting the JNP10K-PWR-DC2 Dip Switches
Field
State
Switch
IP0 is present
On
1
IP0 is not present
Off
IP1 is present
On
2
IP1 is not present
Off
242