Table 58: Setting the JNP10K-PWR-DC2 Dip Switches (continued)
Field
State
Switch
Enabled for 30 A feed; 5500-W for a single feed, 5000-W for dual feeds
On
3
Enabled for 20 A feed; power supply capacity is 3000-W
Off
Figure 141: Setting the Enable Routers for the Power Source
g100597
1
2
2
—
1
—
Power switch, on (|) and standby (O)
Dip switches
19. Verify that the input 1 and 2 LEDs on the power supply faceplate are lit and are on steadily.