Figure 35: LEDs on a JNP10K-PWR-DC Power Supply
3
—
1
—
PWR OK
INP1–Source input 0
4
—
2
—
FAULT
INP2–Source input 1
describes the LEDs in an MX10008.
Table 19: LEDs on a DC Power Supply in an MX10008
Description
State
Color
LED
Indicates that the DC power input voltage is not
within normal operating range.
Blinking
Yellow
INP1 or INP2
DC power is within operating range (-40 VDC to -72
VDC).
Solid
Green
The power supply is switched off.
Off
Unlit
DC power output is within normal operating range.
Solid
Green
PWR OK
DC power output is out of the normal operating
range.
Blinking
Yellow
Power supply has failed and must be replaced.
Solid
Red
FAULT
The power supply is functioning normally. Or, only
one input is powered and the enable router for the
input that is not powered is set to ON. See
“Connecting DC Power to an MX10000” on page 164
for more information on the enable switches.
Off
Unlit
74
Summary of Contents for MX10008
Page 1: ...MX10008 Universal Routing Platform Hardware Guide Published 2019 11 11 ...
Page 19: ......
Page 89: ......
Page 129: ......
Page 170: ......
Page 278: ...5 CHAPTER Troubleshooting Hardware Restoring Junos OS 283 Alarm Messages 287 ...
Page 279: ......
Page 287: ......
Page 318: ...Restricted Access Warning 321 ...
Page 333: ...Jewelry Removal Warning 336 ...
Page 336: ...Operating Temperature Warning 339 ...
Page 345: ...DC Power Disconnection Warning 348 ...
Page 349: ...DC Power Wiring Sequence Warning 352 ...
Page 352: ...DC Power Wiring Terminations Warning 355 ...
Page 361: ...Translation The emitted sound pressure is below 92 dB A per GR63 CORE 364 ...