Management host, such as a PC or laptop, with a serial port (not provided)

(Optional) A grounding cable (minimum 14 AWG (2 mm²), minimum 90°C wire), a grounding lug (Panduit LCC10-14BWL
or equivalent), a pair of 10-32x.25-in. screws, and a pair of flat washers (not provided). For information about installing

the grounding cable, see the NFX250 documentation at

https://www.juniper.net/documentation/product/en_US/nfx250

.

Mount the NFX250

You can mount an NFX250 device on two posts of a 19-in. rack by using the mounting brackets provided with the device.

The device weighs approximately 9.4 lb (4.3 kg). Two persons are required for mounting the device.

1. Attach the ESD grounding strap to your bare wrist and to a site ESD point.

NOTE:

If you are mounting multiple units in the rack, mount the heaviest unit at the bottom and mount the

others from bottom to top in order of decreasing weight.

2. Place the rack in its permanent location, allowing adequate clearance for airflow and maintenance, and secure it to the

building structure.

3. Align the mounting brackets along the front or rear of the side panels of the chassis— depending on whether you will

front-mount or rear-mount the device—and attach the mounting brackets to the chassis by using the mounting screws.

Tighten the screws.

4. Have one person grasp both sides of the device, lift the device, and position it in the rack, aligning the mounting bracket

holes with the threaded holes in the rack rail. Align the bottom hole in each mounting bracket with a hole in each rack

rail, making sure that the chassis is level.

5. Have the second person use the mounting screws (and cage nuts and washers if your rack requires them) to screw the

mounting bracket to the rack.

2

Summary of Contents for NFX250

Page 1: ...ation you need Electrostatic discharge ESD grounding strap not provided One pair of front mounting rails provided Twelve screws to secure the mounting rails and mounting blades to the chassis provided Eight screws to secure the chassis and mounting blades to the rack not provided Screwdriver appropriate for your rack mounting screws not provided An AC power cord with plugs appropriate for your geo...

Page 2: ...s in the rack mount the heaviest unit at the bottom and mount the others from bottom to top in order of decreasing weight 2 Place the rack in its permanent location allowing adequate clearance for airflow and maintenance and secure it to the building structure 3 Align the mounting brackets along the front or rear of the side panels of the chassis depending on whether you will front mount or rear m...

Page 3: ...ce to a grounded AC power outlet by using the power cord The NFX250 device uses a fixed internal AC power supply 2 Set the power switch to the OFF O position 3 Insert the power cord plug into the power source outlet 4 Insert the power cord coupler firmly into the inlet 5 Set the power switch to the ON position 6 Verify that the power LED is lit green and on steadily Step 2 Up and Running IN THIS S...

Page 4: ...he provided RJ 45 cable and RJ 45 to DB 9 serial port adapter The console CON port is located on the management panel of the device The Juniper Device Manager JDM CLI prompt appears NOTE If the boot process is completed before you connected to the console port you might need to press the Enter key for the prompt to appear For more information on JDM see the JDM documentation at https www juniper n...

Page 5: ...me 7 Configure the default gateway edit root jdm set route destination next hop address 8 Configure the IP address and prefix length for the device management interface edit root jdm set interfaces eth0 unit 0 family inet address address prefix length NOTE The management port eth0 is located on the front panel of the NFX250 device 9 Enable Telnet service By default Telnet is not enabled and SSH is...

Page 6: ...er environmental and clearance requirements for the device Before connecting the device to a power source read the installation instructions in the NFX250 documentation The NFX250 device weighs approximately 9 4 lb 4 3 kg Manually installing the device in a rack at a height above 60 in 152 4 cm requires two persons one to lift the device and the second to install the mounting screws To prevent inj...

Page 7: ... Junos are registered trademarks of Juniper Networks Inc in the United States and other countries All other trademarks service marks registered marks or registered service marks are the property of their respective owners Juniper Networks assumes no responsibility for any inaccuracies in this document Juniper Networks reserves the right to change modify transfer or otherwise revise this publicatio...

Reviews: