![background image](http://html1.mh-extra.com/html/juniper/ptx10001-36mr/ptx10001-36mr_hardware-manual_2032720039.webp)
Capacity 3000 W (maximum 3000 W)
PSM 1
Input 1 232 419
Output 11.99 334.33
Capacity 3000 W (maximum 3000 W)
Item Used(W)
Routing Engine 0 26
CB 0 5
System:
Zone 0:
Capacity: 6000 W (maximum 6000 W)
Actual usage: 1023 W
Total system capacity: 6000 W (maximum 6000 W)
PTX10001-36MR AC/HVDC Power Specifications
The PTX10001-36MR operates within the AC/HVDC input voltage range listed in
. The PTX10001-36MR power consumption is listed in
.
Table 12: PTX10001-36MR AC/HVDC Power Specifications
Parameter
Minimum
Rated
Maximum
Input voltage (AC)
180 VAC
200-277 VAC
305 VAC
Input voltage (HVDC)
204 VDC
240-380 VDC
400 VDC
AC input line frequency
47 Hz
50-60 Hz
63 Hz
Table 13: PTX10001-36MR AC/HVDC Power Consumption
Item
Specification
Typical power consumption
1538 W
Maximum power consumption
2164 W
30