5. Ensure the power switch is set to the standby (O) position. This switch turns off the output voltage; it does not interrupt
AC supply.
6. Unscrew the captive screw in the counterclockwise direction by using the Phillips (+) screwdriver, number 1.
7. Rotate the captive screw away from the faceplate of the power supply to release the latch.
NOTE:
You can install the power supplies in any slot labeled PSU 0 through PSU 5 (top to bottom) on a
PTX10008.
8. Using both hands, place the power supply in the power supply slot on the rear of the system.
9. Slide the power supply straight into the chassis until the power supply is fully seated in the slot. Ensure the power
supply faceplate is flush with any adjacent power supply faceplates or power supply cover panels (see
).
10. Push the captive screw into the power supply faceplate. Ensure that the screw is seated inside the corresponding hole
on the faceplate.
11. Tighten the captive screw by turning it clockwise by using the Phillips (+) screwdriver, number 1. When the screw is
completely tight, the latch locks into the router chassis.
Figure 22: Installing a JNP10K-PWR-AC Power Supply in a PTX10008
g050568
Keep latch in open position during installation.