Monitoring the SRX220 Services Gateway Using Chassis Alarm Conditions
When the services gateway detects an alarm condition, the Alarm LED on the front panel
turns red or amber as appropriate.
To view a more detailed description of the cause of the alarm, issue the
show chassis
alarms
command on the command-line interface (CLI).
For more information on the
show chassis alarms
command, see the
describes alarms that can occur for an SRX220 Services Gateway
chassis component.
Table 40: SRX220 Services Gateway Chassis Alarm Conditions and
Corrective Actions
Alarm
Severity
Action
Alarm Condition
Component
Amber (minor)
•
If the CompactFlash card fails at
startup, the services gateway
automatically boots from the
alternative boot device (USB storage
device).
NOTE:
If you configured your
services gateway to boot from an
alternative boot device, ignore this
alarm condition.
•
Reformat the CompactFlash card,
and install a bootable image. (See
the
.)
•
If you did not configure the services
gateway to boot from an alternative
boot device, contact Juniper
Networks Technical Assistance
Center (JTAC). See
Networks Technical Assistance
Center” on page 113
.
The services gateway
boots from an alternate
boot device.
Boot
media
Red (major)
•
Contact the Juniper Networks
Technical Assistance Center (JTAC).
See
Assistance Center” on page 113
.
•
If you must replace the failed
Mini-PIM, see the
Services Gateways for the Branch
Physical Interface Modules
Hardware Guide
for information
about replacing the Mini-PIMs.
A Mini-PIM has failed.
Mini-PIM
109
Copyright © 2016, Juniper Networks, Inc.
Chapter 18: Troubleshooting Components