3. Install the replacement Routing Engine:
a. Power off node 0:
root@node0> request system power-off
b. Wait until a message appears on the console confirming that the services have stopped, and then
physically turn off the power.
c. Label and disconnect all the cables connected to node 0.
d. Replace the Routing Engine.
e. To prevent a split-brain scenario (where the control link is connected while both the nodes are in
the primary state), reconnect only the console cable and the cable to the fxp0 interface. Leave the
rest of the cables disconnected.
f. Ensure that the status of the control link and fabric link on node 1 is down:
root@node1> show chassis cluster interfaces
{primary:node1}
root@node1> show chassis cluster interfaces
Control link status: Down
Control interfaces:
Index Interface Monitored-Status Internal-SA Security
0 em0 Down Disabled Disabled
1 em1 Down Disabled Disabled
Fabric link status: Down
Control interfaces:
Name Child-Interface Status Security
(Physical/Monitored)
fab0 xe-11/0/3 Down / Down Disable
fab0
g. Power on node 0.
4. Load the configuration file, firmware, and scripts file on the new Routing Engine:
a. Insert the USB flash drive into the USB port on node 0, and access the UNIX-level shell on node 0:
root@node0> start shell user root
b. Copy the configuration file, firmware, and scripts file from the USB:
root@node0% cp /var/tmp/usb/config[date] /var/tmp/config[date]
root@node0% cp /var/tmp/usb/junos version /var/tmp/junos version
360
Summary of Contents for SRX5600
Page 1: ...SRX5600 Services Gateway Hardware Guide Published 2020 02 14 ...
Page 23: ......
Page 105: ...LEDs 106 ...
Page 114: ...Figure 51 SRX5K MPC g030309 MPC empty 115 ...
Page 124: ...Port and Interface Numbering 125 ...
Page 130: ...Port and Interface Numbering 131 ...
Page 156: ......
Page 185: ......
Page 193: ...Figure 84 Installing the Front Mounting Hardware for a Four Post Rack or Cabinet 196 ...
Page 239: ......
Page 285: ...c Upload the configuration to RE2 from the USB device 288 ...
Page 372: ...5 CHAPTER Troubleshooting Hardware Troubleshooting the SRX5600 377 ...
Page 373: ......
Page 407: ......
Page 420: ...423 ...
Page 423: ...Restricted Access Area Warning 426 ...
Page 430: ...433 ...
Page 443: ...Jewelry Removal Warning 446 ...
Page 446: ...Operating Temperature Warning 449 ...
Page 456: ...DC Power Disconnection Warning 459 ...
Page 460: ...DC Power Wiring Sequence Warning 463 ...
Page 463: ...DC Power Wiring Terminations Warning 466 ...
Page 466: ...DC Power Disconnection Warning 469 ...
Page 470: ...DC Power Wiring Sequence Warning 473 ...