Reinstalling Components in the SRX5600 Services Gateway Chassis After
Installing It Without a Lift
After the services gateway is installed in the rack, reinstall the removed components before booting and
configuring the services gateway. You reinstall components first in the rear of the chassis, and then in the
front:
1.
Reinstalling Power Supplies After Installing the SRX5600 Services Gateway Without a Lift | 209
2.
Reinstalling the Fan Tray After Installing the SRX5600 Services Gateway Without a Lift | 210
3.
Reinstalling SCBs After Installing the SRX5600 Services Gateway Without a Lift | 211
4.
Reinstalling IOCs, Flex IOCs, and SPCs After Installing the SRX5600 Services Gateway Without a
Reinstalling Power Supplies After Installing the SRX5600 Services Gateway Without a Lift
Reinstall the rightmost power supply first and then work your way to the left. To reinstall the AC or DC
power supplies, follow this procedure for each power supply (see
, which shows the
installation of the DC power supplies):
1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to
one of the ESD points on the chassis.
2. On an AC-powered services gateway, switch the AC input switch on each power supply to the off (O)
position. On a DC-powered services gateway, move the DC circuit breaker on each DC power supply
to the off (O) position.
We recommend this even though the power supplies are not connected to power sources.
3. Using both hands, slide the power supply straight into the chassis until the power supply is fully seated
in the chassis slot. The power supply faceplate should be flush with any adjacent power supply faceplate
or blank installed in the power supply slot.
4. Tighten the captive screws.
209
Summary of Contents for SRX5600
Page 1: ...SRX5600 Services Gateway Hardware Guide Published 2020 02 14 ...
Page 23: ......
Page 105: ...LEDs 106 ...
Page 114: ...Figure 51 SRX5K MPC g030309 MPC empty 115 ...
Page 124: ...Port and Interface Numbering 125 ...
Page 130: ...Port and Interface Numbering 131 ...
Page 156: ......
Page 185: ......
Page 193: ...Figure 84 Installing the Front Mounting Hardware for a Four Post Rack or Cabinet 196 ...
Page 239: ......
Page 285: ...c Upload the configuration to RE2 from the USB device 288 ...
Page 372: ...5 CHAPTER Troubleshooting Hardware Troubleshooting the SRX5600 377 ...
Page 373: ......
Page 407: ......
Page 420: ...423 ...
Page 423: ...Restricted Access Area Warning 426 ...
Page 430: ...433 ...
Page 443: ...Jewelry Removal Warning 446 ...
Page 446: ...Operating Temperature Warning 449 ...
Page 456: ...DC Power Disconnection Warning 459 ...
Page 460: ...DC Power Wiring Sequence Warning 463 ...
Page 463: ...DC Power Wiring Terminations Warning 466 ...
Page 466: ...DC Power Disconnection Warning 469 ...
Page 470: ...DC Power Wiring Sequence Warning 473 ...