Copyright © 2012, Juniper Networks, Inc.
17
Installing and Connecting an Access Point
a.
Solder the ground wire to the ground-wire terminal lug supplied with the lightning
arrestor. Juniper Networks recommends that you use 6-gauge cable for the
ground wire. The ground wire must be properly earthed in order to provide
adequate protection.
b.
Attach the ground-wire terminal lug, lock washer, and hex nut to the lightning
arrestor, in the order shown in Figure 3–4 below.
Figure 3–13. Attaching the Ground-Wire Terminal Lug, Lock Washer, and Hex Nut to
the Lightning Arrestor
c.
Connect one end of the short RF coaxial cable to the WLA622 N-type connector,
and connect the other end to the lightning arrestor.
d.
Connect one end of the 3m RF coaxial cable to the lightning arrestor, and
connect the other end to the outdoor antenna. Continue with step 6.
3.
Connect the antenna to the WLA622 N-type connector using the RF coaxial cable
provided in the antenna package.
4.
Apply weatherproofing tape to the antenna connectors to help prevent water
entering the connectors.
Informational Note:
To meet regulatory requirements, you must ensure that the external
antenna specified with the set ap radio antennatype command exactly matches the
external antenna attached to the WLA622 external antenna port.
To External Antenna
To MP-632
6-gauge
Grounding Cable
Grounding Nut
Locking Washer
Hex Nut
Lightning Protector