Cables and Pinouts
4
Copyright © 2012, Juniper Networks, Inc.
8-Pin DIN to RJ45 Cable Wiring
To construct an extended Ethernet cable to connect from the power injector’s RJ45
Output port to the WLA620 and WLA622’s 8-pin DIN connector, follow the wiring
diagram below. Use Category 5 or better UTP or STP cable, maximum length 100 m
(328 ft), and be sure to connect all four wire pairs.
Figure 5–5. 8-Pin DIN to RJ45 Cable Wiring
WLA632 External Connectors
The WLA632 accepts power from the WLA-XPS9001GO outdoor power supply using
the IP67 multi-pin DIN connector. The WLA632 accepts separate primary 48VDC power
input and Ethernet signal from separate 48VDC and Ethernet input connectors.
The WLA632 48VDC / Ethernet inputs provide primary and secondary lightning
protection on all conductors. The 48VDC / Ethernet inputs to the WLA632 require
lightning protection because the power supply can be up to 100m away.
Ethernet
The WLA632 supports a single IEEE 802.3-compliant auto-sensing 10/100/1000BaseT
Ethernet interface on the Ethernet input connector. It should be configured as auto
MDI/MDIX.
The Ethernet interface supports a cable length of at least 100m over CAT5, CAT5e, or
CAT6 cable.
A watertight RJ45RJ45 is an acceptable alternative to the circular DIN connector for the
Ethernet interface.
The Ethernet cable from the power injector connects to an 8-pin DIN connector on the
WLA620 and WLA622. This connector is described in the following figure and table.
Informational Note:
To construct a reliable Ethernet cable, always use the proper tools or
ask a professional cable supplier to construct the cable.
Any additional cabling used in the assembly should be a minimum UL CMX outdoor-rated or
equivalent.
White/Orange Stripe
Orange
White/Green Stripe
Green
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
8-Pin DIN
Female
RJ-45
1
7
2
3
4
5
8
6
White/Blue Stripe
White/Brown Stripe
Brown
Blue
8-Pin DIN Female
Front View
Caution:
The WLA622 and WLA632 must only be used with a Juniper
Networks-approved WLA-XPS9001GO outdoor power supply in order to prevent possible
damage to the unit.