14
15
SETTING THE RETRACTED HEIGHT
SETTING THE UPPER & LOWER LIMIT
Press the DOWN button on the Handset
(6)
until the desk reaches its lowest position. Measure the distance from the floor
to the desk surface. If the number on the LED display does NOT match your measurement, follow these steps:
Press and hold the DOWN button until the LED display reads „RST“. Press and hold the „M“ button (about 5 seconds) until
the LED displays the flashing starting height. ( If the display returns to „RST“ before the next step is taken, repeat this
step.) Use the UP/DOWN buttons to change the value of the starting height so that it matches your measurement. Wait
about 5 seconds until the display has returned to „RST“.
Finish the reset process by pressing and holding the DOWN button again until the desk lowers a little bit more, slightly
rises and stops. Release the button. The new starting height value is saved and your desk is now ready to use. Note: the
LED display has a tolerance of ± 0.1.
This product has been designed to give you the largest possible range of positions with the lowest and highest settings.
If you prefer the settings at a narrower range, follow these steps:
Make sure the power is ON and a number appears in the LED display (if no number appears, please follow the Reset
procedure described in the USE section).
To Set the Upper-Limit Position:
Use the UP /DOWN buttons to move the table frame to the desired maximum-height position. Press the „M“ button and
release. Press the UP button and release. The LED display will flash „S -“. Press and hold the „M“ button (about 2 seconds)
until the LED display changes to „999“. The display will automatically return to the selected height. The new upper limit is
now set.
To Set the Lower-Limit Position:
Use the UP /DOWN buttons to move the table frame to the desired minimum-height position. Press the „M“ button and
release. Press the DOWN button and release. The LED display will flash „S -“. Press and hold the „M“ button (about 2
seconds) until the LED display changes to „000“. The display will automatically return to the selected height. The new
lower limit is now set.
To Remove the Upper /Lower Limit Positions:
Use the UP/DOWN buttons to move the table frame to the new desired position. Press and hold the „M“ button until the LED
display flashes „S -“ and then release it. Within 5 seconds, press the „M“ button again and hold for 2 seconds. The LED
display will change to „555“ and then automatically return to the height display. The upper and lower limits are now removed.
A RESET procedure lowers the desk to the lowest possible level (regardless of any individually set lower limit). Please
ensure that you have the proper space below the desk.
After the upper and lower limits are set, the previous memory positions ( 1, 2,3, 4) may be outside the new range of
movement. If so, simply reset the memory positions.
If you attempt to alter a previously set upper or lower limit and it is outside of the existing range, you will need to remove
the previously set upper /lower limits first with a reset.
!
HANDSET LOCK
CHANGING ANTI-COLLISION SENSITIVITY
CONVERSION INCHES TO CENTIMETERS
To lock the handset: Press and hold the „M“ button (about 8 seconds) until the LED display switches to „S -“ and then to
„LOC.“ Release the button.
To unlock the handset: Press and hold the „M“ button (about 8 seconds) until the LED switches from „LOC“ to the height
display. Release the button.
Press the DOWN button on the Handset
(6)
until the desk reaches its lowest position. Press and hold the DOWN button
again until the LED display reads „RST“. Press and hold button 2 (about 5 seconds) until the LED flashes „RST“ and then
switches to either:
10.3 = cm or
10.4 = inches
Release button 2. Press and hold button 2 again until the desired setting is reached. Once the chosen setting is displayed,
release the button and wait about 5 seconds for the display to return to „RST“.
Finish the process by pressing and holding the DOWN button until the desk lowers a little bit more, slightly rises and
stops. Release the button. The new measurement setting is saved and your desk is now ready to use.
Press the DOWN button on the Handset
(6)
until the base reaches its lowest position. Press and hold the DOWN button
again until the LED display reads „RST“. Press and hold the UP button (about 5 seconds) while the LED flashes „RST“ and
then switches to either:
10.5 = 10 kg.pressure (most sensitive)
10.6 = 15 kg pressure (middle setting)
10.7 = 20 kg pressure (least sensitive)
Release the UP button. Press and hold the UP button again until the desired setting is reached. Once the chosen setting is
displayed, release the button and wait about 5 seconds for the display to return to „RST“.
Finish the reset process by pressing and holding the DOWN button until the desk lowers a little bit more, slightly
rises a nd stops. Release the button. The new a nti-col l ision sensitivity setting is saved a nd you r desk is now ready
to use.
ENGLISH
ENGLISH