9
—The use of an active carbon filter is
necessary when an exhaust pipe to the
exterior is not available, or when it is not
possible to install this type of pipe.
In the case of the internal recycle version
proceed as follows:
a) Request an active carbon filter suitable
for this model from your supplier.
b) Remove the grill E turning the locks D
and pull it out downwards (fig. 3).
c) To install the filter, fit it in the seat first
upper then lower with the two hooks G
(fig. 4).
d) Re-insert the inlet grill
e) The deflector (fig. 5) must be fitted on the
hole B (fig. 1) fixing it with the screw
provided.
The deflector conveys the air frontwards
avoiding to dirty the rear wall.
Attention
When installed, the hood must be not less
than 65 cm. above electric burners or 75
cm. above gas or mixed-fuel burners.
Warning!
— The hood cannot be connected to flues of
other appliances that run on energy
sources other than electricity.
— When the hood is used at the same time
of other appliances that run on energy
sources other than electricity, provision
must be made for an adequate supply of
air.
— No food must be cooked flambé
underneath the hood.
The use of an unprotected flame is
dangerous for the filters and could cause
fires.
Therefore, never use an open flame under
the hood. When frying foods, never leave
the pan alone because the cooking oil
could flare up.
— Please, keep to the provisions of official
directives regarding the question of fume
discharge.
— The manufacturers refuse to accept any
responsibility for damage to the hood or
its catching on fire because of failure to
observe the above instructions.
GB
View of the hood
1) Flap
2) Grease filter supporting grid
3) Cooking surface lighting
4) Motor speed selector
5) Light switch
Use
Two systems are available:
External exhausting system
In this case the fumes are conveyed outside
by means of a special pipe connected with
the coupling flange A, placed in the hole B
(Fig. 1).
Choosing the exhausting pipe
The coupling ring B has a diameter of
120mm.
We suggest to use Ø 120 mm exhausting
pipe.
According to your installation the pipe can
be directed either towards the ceiling or
towards the walls (fig. 2).
Using the multi-connector C, Ø100, Ø110
and Ø125 mm exhausting pipes can be
used.
Ø 120 mm exhausting pipe: the multi-
connector has not to be fitted.
Ø 125 mm exhausting pipe: insert the
multi-connector on the coupling ring and
remove, using a proper tool, the upper
unused Ø 100 and Ø 110 mm rings of the
multi-connector.
Ø 110 mm exhausting pipe: same
procedure, but removing the Ø 100 mm ring
only.
Ø 100 mm exhausting pipe: apply the
multi-connector on the coupling ring.
Internal recycle version
—The air is purified through an active carbon
filter and returned to the room.
Summary of Contents for JDS 2230
Page 2: ...2 Fig 1 A B Fig 2 Fig 3 5 4 O 1 2 3 O I 1 18 98 1 10 123 C A 1 2 3 3 D E D E ...
Page 3: ...3 Fig 5 Fig 4 F F G G G N1 L L M M Fig 7 Fig 6 0 90 0 54 54 100 Fig 8 L N O P Q R S ...
Page 4: ...4 Fig 9 Fig 10 B B2 B1 C C2 C1 Fig 11 Fig 12 Fig 14 Fig 13 N2 N2 T T 3 H K N3 J Fig 15 U V ...
Page 12: ...LI08PA ELECTROLUX ZANUSSIHAUSGERÄTEGMBH Rennbahnstraße72 74 D 60528Frankfurt ...