REV
.
11
30-05-2017
INSTALLATION
,
USE AND MAINTENANCE MANUAL
JULIA 3000-5000-7000-8000-8500-9000
-
HP
31 / 51
Jurop
SpA
Via Crosera n° 50
33082 Azzano Decimo, PN (Italy)
T
EL
.
+39
0434
636811
F
AX
.
+39
0434
636812
http://www.jurop.it
e-mail: info@jurop.it
Fig. 6.3
• Remove the dirt water that may remain inside the Julia group.
Wash carefully the unit before long periods of stand-by.
• Wash more frequently in case particularly dirty fluids are being
processed.
• The following picture highlight the oil level checks for the different
Julia versions, and show the openings for lubrication oil top ups, drain
and level check (Julia 7000-8000-8500-9000).
Julia 3000/5000 lubrication control points
G
EARBOX LUBRICATION JULIA
3000-5000
1.
Oil fil
2.
Oil discharge
3.
Oil level indicator
Julia 7000-8000-8500-9000 lubrication control points
G
EARBOX LUBRICATION JULIA
7000-8000-8500-9000
1.
Oil fil
2.
Oil discharge
3.
Oil level indicator
Note:
Julia 7000-8000-8500-9000 with centrifugal pump has the oil
level sight glass (pos.3) next to the lower hole.
Julia HP lubrication control points
G
EARBOX LUBRICATION JULIA
HP
1.
Oil fil
2.
Oil discharge
3.
Oil level indicator
Note:
Julia HP with pump (high pressure pumps) has the oil level
sight glass (pos.3) next to the lower hole.
• The following charts report suggested lubrication oil quantities
according to the different Julia models
Suggested lubrication oil quantities for gear box
Without HDR pump
With HDR pump
Julia 3000 - 5000
0,5 l
/
Julia 7000-8000-8500-9000
3 l
2,5 l
Gear box Julia HP
5 l
4,2 l
• Oil level must never be below minimum level: risk of rapid wear of
internal components.
O
PTIMAL LEVEL
M
INIMUM LEVEL
S
IGHT GLASS IN
LOWER POSITION
S
IGHT GLASS IN
UPPER POSITION
O
PTIMAL LEVEL
M
INIMUM LEVEL
W
ASH WITH WATER