Mino I
4810 55 A06

Appliance parameters

Please always specify when ordering spare parts and in the event of any service call-outs! 
In the event of a service call-out, please 

only quote the model number of your stove

. It is worth noting down the version of your new wood 

burning stove now in the circular field provided in the table below. 

Model

Serial

Inspection stamp, date:

Production No. 

JUSTUS GmbH  ·  Oranier Strasse 1  ·  35708 Haiger  ·  Germany

Summary of Contents for Mino I

Page 1: ...293 2925 000 1089 Operating and Installation Instructions for Wood Burning Stoves EN JUSTUS Mino I...

Page 2: ...ire 13 6 Room heating capacity DIN 18893 13 7 Use in Smoke Control Areas 14 7 1 The Clean Air Act 1993 and Smoke Control Areas 14 7 2 Modifications to the air controls for use in Smoke Control Areas 1...

Page 3: ...ickly If you would like to contact us by email or telephone please have the above information ready so the processing of your request can be carried out quickly and easily JUSTUS GmbH Oranier Strasse...

Page 4: ...Keep the oper ating instructions in a safe place so that you can remind yourself of the correct operating procedures when starting a new period of heating Type tested in accordance with EN 13240 Secti...

Page 5: ...tion air supply If necessary the wood burning stove can be equipped with a connection for an ex ternal combustion air supply See Fig 1 For especially well insulated rooms an air supply from outside ca...

Page 6: ...checked by a specialist 3 Flue tube connection and setup of the wood burning stove 3 1 Connection of the flue tube Your wood burning stove can optionally be connected upwards or to the rear To connect...

Page 7: ...objects and for protection of the flooring Note Before heating the system for the first time please remove all documents and accessory parts from the firebox and ash box Remove all stickers so there i...

Page 8: ...fficiency wood BB7 80 1 80 4 CO 1001 385 mg m3 NOx 78 147 mg m3 CnHm 66 73 mg m3 Dust 32 30 mg m3 For Austria For efficiency and emissions values see CE mark Exhaust mass flow 4 8 g s Feed pressure fo...

Page 9: ...ng of the firebox door and the re moval of the trivet to empty the ashes should always be carried out using the tool provided Failure to do so risks injury and burns Heating mode is only permitted whe...

Page 10: ...e it completely This prevents the resulting flue gases from condensing on the viewing pane that is still cold After around 5 10 minutes once the fire has taken hold well carefully open the fire box do...

Page 11: ...tdoor temperatures are above 16 C malfunctions can occur due to a lack of chim ney draught feed pressure In this case use less fuel and open the pri mary air controller wider 5 7 Feed quantities and a...

Page 12: ...ll internal firebricks and deflectors could be removed Push the trivet from beneath and remove it Afterwards remove all bottom firebricks Raise the vermiculite deflector a little A and remove the left...

Page 13: ...ccur if soot de posits in the chimney caused by incomplete combustion ignite Caution chimney fire Immediately shut off all air openings to the wood burn ing stove and call the fire brigade A specialis...

Page 14: ...Department of the Environ ment respectively Further information on the requirements of the Clean Air Act can be found here at https www gov uk smoke control area rules Your local authority is responsi...

Page 15: ...in a reasonable period If there are too few embers in the fire bed add suitable kindling to prevent excessive smoke 7 5 Fuel overloading The maximum amount of fuel specified in this manual should not...

Page 16: ...reed our central customer service team should be notified The repair will generally be carried out at the setup location or under exceptional circumstances at our customer service workshop Ap pliances...

Page 17: ...guli rement Direkte W rmeleistung Direct heat output Puissance thermique directe Indirekte W rmeleistung Indirect heat output Puissance thermique indirecte Energieeffizienzindex EEI Energy efficiency...

Page 18: ...18 Declaration of Performance...

Page 19: ...solid fuel according with Standard requirements carried out by the notified body Name der anerkannten Pr fstelle Name of recognized testing lab EMI T V S D Kft Dugonics utca 11 HU 1043 Budapest Notif...

Page 20: ...ce call outs In the event of a service call out please only quote the model number of your stove It is worth noting down the version of your new wood burning stove now in the circular field provided i...

Reviews: