Maintaining the JUWEL Pump Bioflow
The JUWEL aquarium pump requires little maintenance. Regardless, you should confirm
the functionality at regular intervals.
Please perform the following steps in order to test and maintain the pump:
1. Disconnect the pump and the heater from the power supply.
2. Remove the nozzles.
3. Remove the pump from the pump holder of the filter.
4. Remove the pump housing from the motor and remove the impeller.
5. Thoroughly clean all parts and particularly check the impeller for signs of wear at
the magnet.
6. After that, please reinstall the pump in reverse order in the filter.
BIOFLOW SUPER
D_6_60_Bild
Recommendation:
In order to ensure that the power head operates at its optimum and maintains its
low noise level, we recommend to check and potentially replace the parts subject
to wear and tear, such as the impeller regularly.
All spare parts are available from your local JUWEL Aquarium retailer.
Safety instructions:
Never operate the power head out of water.
Always unplug the power head from the power supply before removing it from the
filter.
The power head is intended for indoor use and for use in fluids up to 35°C.
Never repair the electrical cord or plug. In case of damage replace the complete
power head.
The cover light system JUWEL Violux
You achieve the optimum lighting for your aquarium with the cover light by JUWEL
Aquarium, and it simultaneously offers you access to the aquarium for maintenance
measures while being lit.
The light itself is waterproof; because of that, cover panes against slash water which
would reduce the luminosity are not required.
The cover light by JUWEL Aquarium consists of
- Covering hood (1)
- Compact fluorescent lamp JUWEL Twin-Lite PL4 (15 watts) (2)
- Service hatch (3) for the supply of feed and water treatment agents etc.
Violux_40_PL_Detail
Violux_40_Montage_2
Violux_40_PL_GBW
Vio40_Aufstellen
Violux_40_Detail_Scharnier_Rahmen
3
2
1
Safety instructions:
Do not operate the light under water.
Do not attempt to open the light or repair it in case of a malfunction! This would
endanger the waterproofness.
Install the JUWEL Twin-Lite PL Light unit only in aquarium hoods made by JUWEL
Aquarium from polystyren or ABS to fit the safety requirements using the
specially constructed holders.
Safety instructions:
Pull the power plug for each light replacement.
The connection line may not be repaired. Always replace the entire light in case
of damage.
For Replacement use only original JUWEL Twin-Lite PL Light units!
5