background image

Introduction

 

Thank you for choosing a JUWEL Aquarium product.

 

 

Our products represent over 40 years experience in the manufacturing of aquariums
and their acessories applying most modern production techniques bringing together
the JUWEL Aquarium system, which is both easy to use and simple to maintain.

Important:

Please read this instruction manual carefully and completely to make sure you
have received all components before setting up the aquarium.

 

 

Please observe the safety instructions and maintenance guidelines given in this
manual.

 

 

This instruction manual has been carefully prepared to provide you with accurate
and complete information. All efforts have been made to ensure that the
information given is correct. However, we cannot accept responsibility for
printing or other errors. Technical details are always approximate and are not
warranted characteristics and may be subject to change without notice.

 

 

Always unplug all immersed electrical equipment from mains before placing your
hands into the water.

Important:

The use of additional air stones or air lines is not necessary with the JUWEL
Aquariums. If an air stone is used, this should always be placed in the middle of
the aquarium. Capillary leaks resulting from the use of these items will not be
accepted as a fault with the aquarium.

 

 

Do not transport or move your aquarium while still containing water or sand.

 

 

Always take care not to damage the seals while maintaining your aquarium.

 

 

Do not use toxic substances to clean your aquarium.

Safety instructions:

This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety. Children should be
supervised to ensure that they do not play with the appliance.

Operation with the RC circuit breaker only, max. 30mA.

The power plugs of the electrical devices must not become moist. Connect the
power plugs to the power supply at such a height that the connection cable
forms a loop which would enable the water to drip down.

2

Summary of Contents for Rio 300

Page 1: ...Instruction Manual Rio 300 www juwel aquarium com ...

Page 2: ...fore placing your hands into the water Important The use of additional air stones or air lines is not necessary with the JUWEL Aquariums If an air stone is used this should always be placed in the middle of the aquarium Capillary leaks resulting from the use of these items will not be accepted as a fault with the aquarium Do not transport or move your aquarium while still containing water or sand ...

Page 3: ...e been made to match the dimensions and to bear the weight of the filled aquarium The cabinet must be positioned on a level surface The JUWEL Aquarium is built with a special bottom frame for security The aquarium should be placed directly onto the cabinet DO NOT place any additional support e g polystyrene under the aquarium since this is not necessary with our aquariums Weight of the aquarium in...

Page 4: ... manner that an ideal level of biological filtering is ensured by a sufficient level of percolation through the filter material In that context the large filter volume ensures excellent mechanical filtering and facilitates long cleaning intervals The construction of the filter system enables you to quickly access the individual heater pump and filter media components This way the filter system may...

Page 5: ...r 5 Now start preparing the filter sponges by removing the plastic packaging from the carbon sponge and the nitrate remover sponge and the Cirax filter medium Thoroughly rinse the blue filter sponges only under running water 6 After this insert the blue fine filter sponges and the Cirax filter medium into the lower filter basket Following that place the blue rough filter sponge the green nitrate r...

Page 6: ... organisms in the filtration system it is recommended to exchange the sponge every 6 weeks The nitrate removal sponge contains bacteria which will after a while reduce the nitrate level in the aquarium significantly Important Always use original JUWEL Aquarium filter media to ensure the optimum performance of your system Maintenance of the pump JUWEL Eccoflow in the filter system Bioflow Super 3 0...

Page 7: ...n the heater head You may specify the temperature the heater is supposed to heat the water to in accordance with your individual requirements The centre position between and corresponds to a water temperature of approximately 23 26 degrees Celsius or 74 78 degrees Fahrenheit Please note that depending on the starting temperature of the water in the aquarium it may take approx 12 hours and longer u...

Page 8: ...em The water tightness can only be guaranteed if the tube holders have been firmly connected to their sockets We recommend that you check this prior to connecting the lighting unit to the power supply The light unit can now be placed onto the top frame and can be connected to the power supply Having done this please fit the flaps to close the aquarium completely Notice The JUWEL fluorescent tubes ...

Page 9: ...Caps To ensure the water tightness of your Multilux light system always use genuine JUWEL Aquarium spare parts Please note the tube holders are available from your JUWEL Aquarium retailer In the event of a problem the Multilux light system will automatically switch off If after replacing both light tubes the unit still fails to work then the unit itself will need replacing Please see your aquarium...

Page 10: ...nt If neither repair nor replacement can ensure the performance of the JUWEL Aquarium product the purchaser is entitled to demand a reduction in price or to return the product against repayment of the purchase price 2 Guarantee period and settlement procedure 1 The guarantee period begins on the day of the purchase of the product from the retailer Claims under this guarantee will not be honoured i...

Page 11: ...300 MULTILUX SB 125 Artikel Bestell Nr 3teilig 3 piece 93985 ersetzen 46420 47820 only GB 46720 only AU 92003 86354 High Lite Day 86454 High Lite Nature 86554 High Lite Colour 86654 High Lite Marine 86754 High Lite Blue ...

Page 12: ...JUWEL FILTER SYSTEM Bioflow 6 0_JUWEL Eccoflow Artikel Bestell Nr 85095 85756 85766 only GB 85776 only AU 85615 85815 only GB 85865 only AU 90046 88099 88109 88105 88100 88101 88106 ...

Reviews: