ALPS - Inputs:
AC input power: Directly from the AC Line Filter. The input range is from 220-
240 VAC, at 50/60 Hz.
/LAMP_ENA - from the System Controller PCB. Turns on the ALPS.
/COVER_ON - signal enabling the Arc Lamp Power Supply.
/LAMP_OK - the input is jumpered at the Arc Lamp Power Supply (tied to
ground) so it is always low.
/ = Active Low
ALPS - Outputs:
!
+170 VDC output during the boost phase to get Arc Lamp ignition. This
supplies the power for the Igniter.
!
Run Voltage - 25 to 31 V to maintain the arc lamp operation.
!
Current - 70 to 85 amps to maintain the arc lamp operation.
!
LAMP_OUT - Lamp output voltage, positive.
!
LAMP_RTN - Lamp return.
!
/LAMP_LIT - signal to System Controller PCB indicating that the Arc Lamp
is lit.
!
/LAMP_OK - signal to System Controller PCB (no real indication).
Summary of Contents for 250
Page 16: ...Chapter 2 System Description Model 250 Service Manual 2 9 ...
Page 43: ...Chapter 4 Optical 4 10 Model 250 Service Manual Figure 4 6 Optical Path ...
Page 55: ...Chapter 5 Optical 3 4 22 Model 100 Service Manual ...
Page 91: ...Chapter 5 Electronics 5 36 Model 250 Service Manual Figure 5 22 Scan Reversal PCB I O Diagram ...
Page 131: ...Chapter 5 Electronics 5 76 Model 250 Service Manual Figure 5 44 Backplane Diagram right side ...
Page 132: ...Chapter 5 Electronics Model 250 Service Manual 5 77 ...
Page 138: ...Chapter 6 Miscellaneous Items 6 6 Model 250 Service Manual ...
Page 167: ...Chapter 7 Troubleshooting Model 250 Service Manual 7 29 ...
Page 181: ...Chapter 8 Software and Protocol 8 14 Model 250 Service Manual ...
Page 185: ...Chapter 9 Parts List 9 4 Model 250 Service Manual ...