1-24 (No. 52197)
Item
Measuring
instrument
Test point
Adjustment part
Description
V. HEIGHT
adjustment
[3. DEF]
2. VER. HEIGHT
13. V. ZOOM
– PAL V. HEIGHT –
(1) Receive a PAL cross-hatch signal.
(2) Select
2. VER. HEIGHT
.
(3) Set the initial setting value of
2. VER. HEIGHT
.
(4) Select
13. V. ZOOM
.
(5) Set the initial setting value of
13. V. ZOOM
.
(6) Adjust
13. V. ZOOM
and make the vertical screen size
92% of the picture size.
– NTSC V. HEIGHT –
(1) Receive a NTSC cross-hatch signal.
(2) Make similar adjustment of NTSC V. HEIGHT in the same
way as for “PAL V. HEIGHT”.
Signal
generator
Remote
control unit
H. POSITION
adjustment
– PAL H. POSITION –
(1) Receive a PAL circle pattern signal.
(2) Select
5. HOR. POSITION
.
(3) Set the initial setting value of
5. HOR. POSITION
.
(4) Adjust
5. HOR. POSITION
to make “
C = D
”.
– NTSC H. POSITION –
(1) Receive a NTSC circle pattern signal.
(2) Make similar adjustment of NTSC H. POSITION in the
same way as for “PAL H. POSITION”.
Signal
generator
Remote
control unit
H. WIDTH
adjustment
[3.DEF]
6. HOR. WIDTH
– PAL H. WIDTH –
(1) Receive a PAL cross-hatch signal.
(2) Select
6. HOR. WIDTH
.
(3) Set the initial setting value of
6. HOR. WIDTH
.
(4) Adjust
6. HOR. WIDTH
and make the horizontal screen
size 91% of the picture size.
– NTSC H. WIDTH –
(1) Receive a NTSC cross-hatch signal.
(2) Make similar adjustment of NTSC H. WIDTH in the same
way as for “PAL H. WIDTH”.
Signal
generator
Remote
control unit
Screen size 91%
Picture size 100%
Screen
size
92%
Picture
size
100%
C
D
[3. DEF]
5. HOR. POSITION