1-22 (No.YA466)
H. SIZE
Signal
generator
Remote
control unit
[4.DEF]
5. H-SIZE
PAL H. SIZE
(1) Receive a PAL crosshatch signal.
(2) Select
4. DEF
from the SERVICE MODE.
(3) Select
<5. H-SIZE>
.
(4) Set the initial setting value of
<5. H-SIZE>
.
(5) Adjust
<5. H-SIZE>
to make the horizontal screen
size to
91%
of the picture size.
(6) Press the
[OK]
key to memorize the set values.
NTSC H. SIZE
(1) Receive a NTSC crosshatch signal.
(2) Follow the same step 2 to 6 as in PAL H. SIZE.
SIDE PIN
Signal
generator
Remote
control unit
[4. DEF]
7. EW-PIN
PAL SIDE PIN
(1) Receive a PAL crosshatch signal.
(2) Select
4. DEF
from the SERVICE MODE.
(3) Select
<7. EW-PIN>
.
(4) Set the initial setting value of
<7. EW-PIN>
.
(5) Adjust
<7. EW-PIN>
so that the first vertical lines at
the left and right edges on the screen are straight.
(6) Press the
[OK]
key to memorize the set values.
NTSC SIDE PIN
(1) Receive a NTSC crosshatch signal.
(2) Follow the same step 2 to 6 as in PAL SIDE PIN.
TRAPEZIUM
Signal
generator
Remote
control unit
[4.DEF]
6. TRAPEZ
PAL TRAPEZIUM
(1) Receive a PAL crosshatch signal.
(2) Select
4. DEF
from the SERVICE MODE.
(3) Select
<6. TRAPEZ>
.
(4) Set the initial setting value of
6. TRAPEZ
.
(5) Adjust
<6. TRAPEZ>
so that the vertical lines at the
left and right edges on the screen are in parallel.
(6) Press the
[OK]
key to memorize the set values.
NTSC TRAPEZIUM
(1) Receive a NTSC crosshatch signal.
(2) Follow the same step 2 to 6 as in PAL TRAPEZIUM.
Item
Measuring
instrument
Test point
Adjustment part
Description
Screen size 91%
Picture size 100%
Straight
Parallel