1-24 (No.YA447)
COMPRESS : ON (16:9)
H. BOW
Signal
generator
Remote
control unit
[4.DEF]
11. BOW
PAL H. BOW
(1) Receive a PAL crosshatch signal.
(2) Select
4. DEF
from the SERVICE MODE.
(3) Select
<11. BOW>
.
(4) Set the initial setting value of
<11. BOW>
.
(5) Adjust
<11. BOW>
to optimize the horizontal arc
distortion.
(6) Press the
[OK]
key to memorize the set values.
NTSC H. BOW
(1) Receive a NTSC crosshatch signal.
(2) Follow the same step 2 to 6 as in PAL H. BOW.
Item
Measuring
instrument
Test point
Adjustment part
Description
Straight
Item
Measuring
instrument
Test point
Adjustment part
Description
V. SIZE
Signal
generator
Remote
control unit
[4.DEF]
14. V. ZOOM
3. V-SIZE
PAL V. SIZE
(1) Receive a circle pattern signal of vertical frequency
50Hz (PAL).
(2) Set the COMPRESS(16 : 9) to ON.
(3) Select
4. DEF
from the SERVICE MODE.
(4) Set the initial setting value of
<14. V. ZOOM>
.
(5) Select
<3. V-SIZE>
.
(6) Set the initial setting value of
<3. V-SIZE>
.
(7) Adjust
<3. V-SIZE>
to set the vertical amplitude of
the image to the value shown in the left hand side
list.
(8) Press the
[OK]
key to memorize the set values.
NTSC V. SIZE
(1) Receive a crosshatch signal of vertical frequency
60Hz (NTSC).
(2) Follow the same step 2 to 8 as in PAL V. SIZE.
V. SLOPE
Signal
generator
Remote
control unit
[4.DEF]
2. V-SLOPE
PAL V. SLOPE
(1) Receive a circle pattern signal of vertical frequency
50Hz (PAL).
(2) Set the COMPRESS(16 : 9) to ON.
(3) Select
4. DEF
from the SERVICE MODE.
(4) Select
<2. V-SLOPE>
.
(5) Set the initial setting value of
<2. V-SLOPE>
.
(6) Adjust
<2. V-SLOPE>
to make "
A = B
".
(7) Press the
[OK]
key to memorize the set values.
NTSC V. SLOPE
(1) Receive a circle pattern signal of vertical frequency
60Hz (NTSC).
(2) Follow the same step 2 to 7 as in PAL V-SLOPE.
Screen size
Vertical
amplitude
Vertical amplitude
Screen
size
AV-2986ME
AV-29MS26
AV-29MX76/G
305 mm
B
A
Blanking line
Summary of Contents for AV-2986ME