No.52003
AV-36F703
AV-36F713
AV-36F803
28
Item
Measuring
instrument
Test point
Ad justment part
Description
SUB BRIGHT
adjustment
Remote
control unit
S01:BRIGHT
1. Receive the broadcast and set the STANDARD mode.
2. Enter the SERVICE MENU.
3. Select
S01:BRIGHT
of the V/C(S) mode.
4. Set the initial s etting value of the
S01:BRIGHT
with the
FUNCTION / key.
5. If the brightness is not the best with the initial s etting value,
make fine adjustment of the
S01:BRIGHT
until you get the
optimum brightness .
SUB
CONT RAST
adjustment
Remote
control unit
S02:PICTURE
1. Receive the broadcast and set the STANDARD mode.
2. Enter the SERVICE MENU.
3. Select
S02:PICTURE
of the V/C(S) mode.
4. Set the initial setting value of the
S02:PICTURE
with the
FUNCTION / key.
5. If the c ontrast is not the bes t with the initial setting value, make
fine adjus tment of the
S02:PICTURE
until you get the optimum
contrast.
[ Method of adjustment without measuring instrument ]
SUB COLOR
adjustment
Signal
generator
Remote
control unit
S03:COLOR
1. Receive the broadcast.
2. Enter the SERVICE MENU.
3. Select
S03:COLOR
of the V/C(S) mode.
4. Set the initial setting value of the
S03:COLOR
with the
FUNCTION / key.
5. If the color is not the best with the Initial s etting value, make fine
adjustment of the
S03:COLOR
until you get the optimum color.
[ Method of adjustment using measuring instrument ]
Signal
generator
Oscilloscope
Remote
control unit
TP-B
TP-E(
#
#
#
#
)
[CRT
SOCKET
PWB]
S03:COLOR
1. Input the full field c olor bar signal (75% white).
2. Enter to the SERVICE MENU.
3. Enter to the 9.RF AFC mode and set the AFC to OFF.
4. Select
S03:COLOR
of the V/C(S) mode.
5.
Set the initial s etting value of the
S03:COLOR
with the
FUNCTION / key.
6. Connect the osc illosc ope between
TP-B
and
TP-E
.
7. Adjust
S03:COLOR
and bring the value of
(A)
in the illustration
to
+24V
.
8. Reset the RFAFC setting pos ition from OFF to ON.
Ad justment item
Initial setting value
S01 BRIGHT
64
Ad justment item
Initial setting value
S02 PICTURE
60
Ad justment item
Initial setting value
S03 COLOR
50
(A)
W
Cy
G
Mg
B
R
Y
0V
(
-
)
(
+
)