No. 51914
AV-48WP30
43
Item
Measuring
Instrument
Test point
Adjustment Item
Description
*
Select the STANDARD mode (all "000") on the VIDEO
STATUS.
WHITE
BALANCE
(High Light)
adjustment
Signal generator
Remote
control unit
S10 : R DRIVE
S12 : B DRIVE
1. Receive the NTSC black and white signal (color off).
2. Select that COLOR TEMP is set at the LOW mode.
3. Select the 4.HIGH-LIGHT, and set the initial setting
values of the WHITE BALANCE (S10 & S12 of HIGH
LIGHT) on the SERVICE MENU.
4. Press the 0 key, then setting values appear.
5. Make sure that the WHITE BALANCE tracking from the
LOW-LIGHT through the HIGH-LIGHT has been
properly done. (When the black and white signal
(color off) is received, the natural white should be
visible.)
6. Input the 1080i which and black signal.
7. Repeat steps 3.
~
5. above.
8. Input the 480i black and white signal.
9. Repeat steps 3.
~
5. above.
10. Press the MUTING key and memorize the set values.
1
2
3
4
5
6
7
8
9
R DRIVE
B DRIVE
EXIT
B DRIVE
R DRIVE
REMOTE CONTROL UNIT
0
OSD ON / OFF
Fig.2
HW-BAL
***
***
Fig.1
R DRIVE
setting
value
G DRIVE
setting
value
Setting
ITEM
Press 0 key then appear.
INITIAL SETTING VALUE
Setting value (STANDARD LOW)
Item
NTSC
480i
1080i
S10
080
080
078
S12
074
074
070
Summary of Contents for AV-48WP30
Page 1: ......