AV-N29304
AV-N29430
1-16 (No.52129)
3.5 INITIAL SETTING VALUE OF SERVICE MENU
(1) Adjustment of the service menu is made on the basis of the initial setting values. however, the new setting values which displays
on the screen in its optimum condition may differ from the initial setting value.
(2) Do not change the initial setting values of the items not listed in "ADJUSTMENT PROCEDURE".
(3) "---" is impossible to adjust.
3.5.1 [1.V / C]
[AV-N29304]
[AV-N29430]
No.
Setting item
Variable range
Initial setting value
RF
EXTERNAL (SV,CV)
COMPONENT
STANDARD
THEATER
STANDARD
THEATER
STANDARD
THEATER
S01
BRIGHT
0~127
64
---
---
---
---
---
S02
PICTURE
0~127
65
---
---
---
---
---
S03
COLOR
0~127
45
---
---
---
55
---
S04
TINT
0~127
60
---
---
---
63
---
S05
DETAIL
0~63
35
---
40
---
40
---
S06
-
-128~+127
---
0
1
---
+1
---
S07
PICT+-
-128~+127
---
-15
0
---
0
---
S08
COLOR +-
-128~+127
---
-3
1
---
---
---
S09
TINT+-
-128~+127
---
-6
-3
---
---
---
S10
-
-128~+127
---
+3
---
---
---
---
No.
Setting item
Variable range
Initial setting value
RF/EXT (SV,CV)
COMPONENT
STANDARD
THEATER
STANDARD
THEATER
LOW
HIGH
LOW
HIGH
LOW
HIGH
LOW
HIGH
S11
R CUT OFF
0~255
30
---
---
---
---
---
---
---
S12
G CUT OFF
0~255
30
---
---
---
---
---
---
---
S13
B CUT OFF
0~255
30
---
---
---
---
---
---
---
S14
R DRIVE
0~127
64
---
---
---
---
---
---
---
S15
B DRIVE
0~127
64
---
---
---
---
---
---
---
S16
R CUT+-
-128~+127
---
0
0
0
0
---
---
---
S17
G CUT+-
-128~+127
---
0
0
0
0
---
---
---
S18
B CUT+-
-128~+127
---
0
0
0
0
---
---
---
S19
R DRV+-
-128~+127
---
+5
+13
+7
0
---
---
---
S20
B DRV+-
-128~+127
---
+6
-25
-9
0
---
---
---
No.
Setting item
Variable range
Initial setting value
RF/EXT (SV,CV)
COMPONENT
STANDARD
THEATER
STANDARD
THEATER
LOW
HIGH
LOW
HIGH
LOW
HIGH
LOW
HIGH
S11
R CUT OFF
0~255
30
---
---
---
---
---
---
---
S12
G CUT OFF
0~255
30
---
---
---
---
---
---
---
S13
B CUT OFF
0~255
30
---
---
---
---
---
---
---
S14
R DRIVE
0~127
64
---
---
---
---
---
---
---
S15
B DRIVE
0~127
64
---
---
---
---
---
---
---
S16
R CUT+-
-128~+127
---
0
0
0
0
---
---
---
S17
G CUT+-
-128~+127
---
0
0
0
0
---
---
---
S18
B CUT+-
-128~+127
---
0
0
0
0
---
---
---
S19
R DRV+-
-128~+127
---
0
+7
+7
0
---
---
---
S20
B DRV+-
-128~+127
---
0
-9
-9
0
---
---
---
No.
Setting item
Variable range Initial setting value
S21
AGC ADJUST
0~127
80