No. 51944
AV28CH1EUS
AV28CH1EUB
27
Item
Measuring
instrument
Test point
Ad justment part
Description
Ad justment
of TRAPEZ
Signal
generator
Remote
control unit
5.TRAPEZ
26. Receive a cross -hatc h signal.
27. Select 5.TRAPEZ with the FUNCTION UP/DOWN key.
28. Set the initial setting value of TRAPEZ with the FUNCT ION
- or + key.
29. Adjust TRAPEZ and bring the VERTICAL lines at the right
and left edges of the screen parallel .
30. Press the MENU key and memoriz e the s et value.
Ad justment of
COR. UP/LO
Signal
generator
Remote
control unit
7.COR-PIN
8.COR-UP
9.COR-LO
31. Select 8.COR-UP with the FUNCTION UP / DOW N k ey.
32. Set the initial setting value of COR.-UP with the FUNCTION
- or + key.
33. Adjust COR-UP, and bring the straight line at the upper
corner.
34. Select 9.COR-LO with the FUNCTION UP / DOWN key.
35. Set the initial setting value of COR-LO with the FUNCTION
- or + key.
36. Adjust COR-LO, and bring the straight line at the low corner.
37. Press the MENU key and memoriz e the s et value.
38. If the extream upper & lower c orners are a little pin or barrel
chose 7.COR-PIN and adjust.
39. Press the MENU key and memoriz e the s et value
Ad justment
of ANGLE
10. ANGLE
•
In case where there is a parallelogrammical distortion of
images on the screen.(FigA)
40. Select 10.ANGLE with the FUNCTION UP / DOWN key.
41. Adjust ANGEL, and bring the VERTICAL lines straight..
42. Press the MENU key and memoriz e the s et value.
Parallel
Straight
Straight
Fig. A