32
12.18 Sleep Time :
’
U12
’
(55H 31H 32H)
Definition
:
Sets the sleep time
Command
:
’U12’(55H 31H 32H)
Parameter type
:
(*)
Reply time
:
3seconds
Conditions
:
Operation mode
Standby
mode Power ON mode
Cool-down mode
Emergency mode
O O
O
X
The "Sleep time" function automatically turns off the projector power if the no-signal status continues for a
specified time.
*Available parameters
Sleep time can be set to any of the following:
15 min., 30 min., 60 min., and 0 min.
When the above times are represented as numerical parameters:
Character
HEX
15min.
‘000F’
30H 30H 30H 46H
30min.
‘001E’
30H 30H 31H 45H
60min.
‘003C’
30H 30H 33H 43H
0min.
‘0000’
30H 30H 30H 30H
The sleep time function is disabled when the time is set to “0 min”.
#Tally (Response) data format to current sleep time query
‘@’ ‘1’ SP Normal Termination Status SP Parameter 1 SP Parameter 2 CR
Parameter 1
:
Indicates the sleep time specified
(Refer to "Available parameters")
Parameter 2
:
Indicates the remaining sleep time.
Parameter type is numeric.
# Communication Examples
◇
When specifying "30 min." as the sleep time
CTLR ‘!’ ‘1’ SP ‘U12’ SP ‘001E’ CR
DLA ‘@’ ‘1’ SP ‘0’ CR
◇
When requesting the current sleep time setting (if the sleep time is set to "15 min." and the
remaining time is 3 min.)
CTLR ‘?’ ‘1’ SP ‘U12’ CR
DLA ‘@’ ‘1’ SP ‘0’ SP ‘000F’ SP ‘0003’ CR