3
no parameter for tally (response) data in response to a command.
3.2.2
Tally Data when Error Occurs
Header ID SP Error Status CR
Header
:
Indicates the beginning of the tally (response) data
‘@’(40H)
ID
:
Identification number of Projector
SP
:
Indicates the separation between ID and Status(20H)
Error
:
‘A00’ (41H 30H 30H)
Status
‘A01’ (41H 30H 31H)
‘A02’ (41H 30H 32H)
‘A03’ (41H 30H 33H)
‘A04’ (41H 30H 34H)
‘A05’ (41H 30H 35H)
‘A0A’ (41H 30H 41H)
‘A0B’ (41H 30H 42H)
CR
:
Indicates the end of the data(0DH)
*For details on error status, refer to 8. Tally (Response) Data.
3.3
Internal Error Data Format (Projector to External Control)
Header ID SP Internal Error Status SP Parameter SP Parameter SP
・・
CR
Header
:
Indicates the beginning of the internal error data
‘
&
’(26H)
ID
:
Identification
of
Projector
SP
:
Indicates the separation between ID and status, status and parameter,
parameter and parameter(20H)
Internal
Error
:
‘E01’ (45H 30H 31H)
Status
‘E02’ (45H 30H 32H)
‘E03’ (45H 30H 33H)
‘E04’ (45H 30H 34H)
‘E06’ (45H 30H 36H)
‘E07’ (45H 30H 37H)
‘E08’ (45H 30H 38H)
‘E09’ (45H 30H 39H)
‘E0B’ (45H 30H 42H)
‘E0C’ (45H 30H 43H)
‘E11’ (45H 31H 31H)
‘E12’ (45H 31H 32H)
‘E20’ (45H 32H 30H)
CR
:
Indicates the end of the data(0DH)
* For details on internal error status, refer to 9. Internal Errors.