3-5
Signal
(A1)
•
Ext. input
(A2)
•
Color(colour) bar signal[PAL]
Mode
(B)
•
SP
Equipment
(C)
•
Oscilloscope
Measuring point
(D)
•
TP8602 or CN8601 pin 1
[Digital board]
Adjustment part
(F)
•
VR8604
[Digital board]
Specified value
(G)
•
1.02 ± 0.05 Vp-p
(1) Record the signal (A2) in the mode (B), and play back
the recorded signal.
(2) Observe the waveform at the measuring point (D).
(3) Adjust the adjustment part (F) so that the Y level becomes
the specified value (G).
3.4.2 HDD PB Y level
Fig.3-4-2a HDD PB Y level
H. rate
Y level
Signal
(A1)
•
Ext. input
(A2)
•
Color(colour) bar signal [PAL]
Mode
(B)
•
SP
Equipment
(C)
•
Oscilloscope
Measuring point
(D)
•
TP8601 or CN8601 pin 3
[Digital board]
Adjustment part
(F)
•
VR8603
[Digital board]
Specified value
(G)
•
300 ± 30mVp-p
(1) Record the signal (A2) in the mode (B), and play back
the recorded signal.
(2) Observe the waveform at the measuring point (D).
(3) Adjust the adjustment part (F) so that the burst level be-
comes the specified value (G).
3.4.3 HDD PB C burst level
Fig.3-4-3a HDD PB C burst level
Burst level
H. rate
3.5 AUDIO CIRCUIT
Notes:
• This adjustment should be done after the “REC color
(colour) level adjustment” for the video circuit has
been completed.
• GND (Ground) should be taken from the Tuner shield
case.
Signal
(A1)
•
Ext. input
(A2)
•
Audio: No signal
(A3)
•
Video: Color (colour) bar signal [PAL]
Mode
(B)
•
S-VHS EP
Equipment
(C)
•
Oscilloscope
Measuring point
(D)
•
TP2253 (A. FM)
External trigger
(E)
•
TP111 (D.FF)
EVR mode
(F1)
•
Jig RCU: Code “57”
EVR address
(F2)
•
A: 30 (Press remote controller “3”
and “0” keys.)
Specified value
(G1)
•
400 ± 100 mVp-p
(G2)
•
More than 250 mVp-p
Adjustment tool
(H)
•
Jig RCU [PTU94023B]
•
Digit-key remote controller
(1) Apply the external trigger signal to D.FF (E) to observe
the Audio PB FM waveform at the measuring point (D).
(2) Record the signal (A3) with no audio signal input in the
mode (B), and play back the recorded signal.
(3) Press the channel buttons (+, –) simultaneously to enter
the manual tracking mode. This also brings tracking to
the center (centre).
(4) If the A.PB FM level is not within the specified value (G1),
perform the adjustment in a following procedure.
(5) Set the VCR to the EVR mode by transmitting the code
(F1) from the Jig RCU.
(6) Set the EVR address to (F2) by pressing the button of
the digit-key remote controller.
(7) Adjust with the channel buttons (+, –) on the VCR (or on
the remote controller) so that the A.PB FM level of the
higher channel level becomes the specified value (G1).
(Adjust before recording, then confirm it by playing back.)
(8) If the specified value (G1) is not obtained, adjust with the
channel buttons (+, –) so that the waveform level of the
lower channel level becomes the specified value (G2).
(Adjust before recording, then confirm it by playing back.)
(9) Release the EVR mode of the VCR by transmitting the
code (F1) from the Jig RCU again. (When the EVR mode
is released, the adjusted data is memorized.)
3.5.1 Audio REC FM
Fig. 3-5-1a Audio REC FM
V. rate
Specified
value (G1)
Specified
value (G2)