background image

(1/2) 

 

 

TP 8/12/11 

JVC  U.S.A. 

 

Customer Care Center 1-800-252-5722 

CUSTOMER PROCEDURE  

 

 

“Chk Wiring then reset unit” message scrolls on display when unit is powered ON  
 

 

KD-R320J 

KD-R420J 

KD-R520J 

KD-HDR44J 

KD-BPT30J 

KD-R328J 

 

 

KD-R428J 

KD-R528J 

KD-BTP50J 

KD-A525J 

KD-A625J 

KD-R620J 

 

 

KD-R628J 

KD-AHD79J 

KD-HDR70J 

KW-HDR720J 

 

 

 

Cause 

The wires were shorted during installation. 
 

Cure 

1.

 

Remove the Radio and disconnect the Harness. 
 

2.

 

Verify the Units wiring and ensure there are no shorts. 

 

Check for misconnection (for example; DC12V to Left speaker negative to 
reverse signal) 

 

Check for loose connections 

 

Check for uncovered connections 
 

3.

 

Clear the error using the procedure below. 

 

 

PROCEDURE 

Apply this procedure after verifying the units wiring.  
It is NOT possible to clear the error message if the wiring problem has not been 
corrected. 

1.

 

Remove wiring harness from unit (remove all DC power). 
 

2.

 

Simultaneously press and hold the [MENU] and [UP arrow] button. 
 

3.

 

While holding [Menu] / [Up arrow] buttons, insert the unit’s wiring harness 
(reapply DC power to the unit). 

a.

 

 “DC ERR” will be displayed. 

b.

 

If “Chk wiring…” message reappear, retry steps 1-3 again. 

 