Test method
1.
.
Check the voltage and frequency of the secondary
toroidal coil.
2. Measure the secondary toroidal coil, if the standard
frequency value of 22.87 kHz ± 50 Hz is not attained,
measure the R60 terminal, then adjust the SV01 so
that the R60 terminal becomes 22.87 kHz ± 50Hz.
Note:
TEST SET
FREQUENCY COUNTER
MAIN PCB
(+)
(-)
POWER SUPPLY
14.4V
60Vp-p
±2.5V
DC/DC CONVERTER SECOND GENERATOR SWITCHING
TEST ITEM
VOLTAGE TEST
FREQUENCY CHECK
60Vp-p±2.5V
22.87KHz±50Hz
OSCILLOSCOPE
VOLT/DIV: 10
TIME/DIV: 10mcec
SPECIFICATION
CONDITION
FREQUENCY:22.87kHz ± 50Hz
VOLTAGE VALUE:60Vp-p ± 2.5V
When measuring, adjust and apply power
with no signal or load on each board.
5
6
7
3
R01
R60
R03
C01
J09
Q01
C31
C68
Measuring
Points
MAIN PCB
Summary of Contents for KS-AX4500