20
Installation and connection
When mounting the camera directly to
the ceiling or on the wall
When mounting to a wall, replace areas indicated
as “ceiling” in the procedures by “wall”.
䡵
Setup
1.
Open a hole in the ceiling. (
R
30 mm, 1 1/8
inches)
Make use of the template supplied to open a hole.
2.
Draw the fall prevention wire mounted to
the ceiling slab and the cable out from the
CAUTION:
ceiling in advance.
●
Select a suitable fall prevention wire based
on length, strength, location, material
(insulation property), etc.
●
Use a ring on the fall prevention wire for
mounting to the camera unit with an
internal diameter of at least
R
3.1 mm or
and not larger than
R
5.5 mm, and an
external diameter that is not larger than
R
9 mm.
3.
Remove the dome cover.
As illustrated in the diagram, hold the dome
ring such that the position mark comes
between the thumb and index finger. Turn the
ring in the counterclockwise direction to
remove.
4.
Remove the inner dome
The inner dome is secured with claws
(3 locations). Hold the inner dome and remove
it from the claws.
5.
Remove the outer case.
A
Loosen the camera fastening screw with a
screwdriver.
B
To remove, turn the camera unit in the
counterclockwise direction.
C
Dismantle the fall prevention wire.
6.
Loosen the pan fastening screw.
CAUTION:
●
Moving the lens unit without loosening the
pan fastening screw may damage the lens
unit.
7.
Set the switches for video images.
(TK-C215V4
A
pg. 10)
(TK-C215V12
A
pg. 12)
䡵
Connecting
1.
Align
j
with the shooting direction when
mounting the outer case to the ceiling.
2.
Hang the fall prevention wire that has been
dismantled in Step 5
C
of the setup
procedures to the hook.
3.
Attach the fall prevention wire to the
camera.
(Fall prevention wire is not included)
CAUTION:
●
Tighten all screws securely. Otherwise the
camera may come loose and fall.
Mounting the Camera
(continued)
3.
Dome Ring
Position mark
Notes on outer case mounting screws
(not supplied):
●
Height of screw head should be less than 4
mm.
●
The diameter of the attachment hole of
outer case is
R
4.5 mm (3/16 inch).
●
Do not use flathead screws.
●
When using an impact screwdriver, do not
tighten the screws fully. Tighten using your
hand instead. Failure to do so may damage
the outer case.
A
5.
7.
5.
4.
B
6.
C
Camera
Fastening
Screw
Pan fastening
Screw
Inner Dome
Claws
(3 locations)
*TK-C215V4 is used in the above illustration.
TK-C215V4_V12_EN.book Page 20 Wednesday, August 2, 2006 1:18 PM