1-24 (No.YA301)
4.7.2 MTS CIRCUIT
Item
Measuring
instrument
Test point
Adjustment part
Description
MTS INPUT
LEVEL
Remote
control unit
[1.ADJUST]
T001: IN LEVEL
(1) Receive the any broadcast.
(2) Select
"1.ADJUST"
from the SERVICE
MODE.
(3) Verify that the
< T001 >
(IN LEVEL) is set at its
initial setting value.
(4) Press the
[MUTING]
key to memorize the set
value.
MTS
SEPARATION
TV audio
multiplex
signal
generator
Oscilloscope
Remote
control unit
L OUT
R OUT
[1.ADJUST]
T002: LOW SEP
T003: HI SEP
(1) Input the stereo L signal (300Hz) from the TV
audio multiplex signal generator to the antenna
terminal.
(2) Connect an oscilloscope to
L OUT
pin of the
AUDIO OUT
, and display one cycle portion of
the 300Hz signal.
(3) Change the connection of the oscilloscope to
R OUT pin of the
AUDIO OUT
, and enlarge the
voltage axis.
(4) Select
"1.ADJUST"
from the SERVICE
MODE.
(5) Set the initial setting value of the
< T002 >
(LOW SEP).
(6) Adjust the
< T002 >
so that the stroke element
of the 300Hz signal will become minimum.
(7) Change the signal to 3kHz, and similarly ad-
just the
< T003>
(HI SEP).
(8) Press the
[MUTING]
key to memorize the set
value.
L-Channel
signal waveform
R-Channel
crosstalk portion
Minimum
1 cycle