SECTION 3
ADJUSTMENTS
3.1 ADJUSTMENT PREPARATION
(1) Adjustment of many Majority of the adjustment items for
this unit is performed using the remote control.
(2) However, adjustment of some adjustment items is
performed in the conventional way, i.e. with components
on the boards.
(3) Ensure that the power supply is AC220V.
(4) Allow the set and the measuring devices to run for at least
30 minutes.
(5) Do not alter settings of items/preset values on the service
screen that are not stated in this manual.
(6) Unless otherwise stated in the “ADJUSTMENT
PROCEDURE” section, follow the settings for the features
stated below using the remote control.
3.2 MEASURING INSTRUMENT AND FIXTURES
• DC voltmeter (or Digital voltmeter)
• Oscilloscope
• Signal generator (Pattern generator)
• Remote control unit
3.3 MAIN PARTS LOCATIONS (RECEIVER UNIT)
Fig.1
Setting item
Settings
PICTURE MODE
STANDARD
PICTURE adjustment
All center (00)
WHITE BALANCE
MID
DIGITAL VNR
AUTO
Super Digi Pure
AUTO
SOUND adjustment
All centre (00)
ZOOM
FULL
MAIN PWB
MI-COM PWB
MI-COM
INTERFACE
PWB
DIST RELAY PWB
FRONT CONTROL PWB
RECEIVER POWER PWB
AV SW PWB
AV JACK PWB
SUB TUNER PWB
DIST PWB