SW-D7000U, 9CH. COLOR VIDEO MULTIPLEXER
52 JVC PROFESSIONAL, IMAGING PRODUCTS
If it is necessary for the operator to be able to clear active alarms, and Transparent mode is
preferred, then rather select timed-out alarms instead of transparent alarms in the ALARM
LATCHING menu, and set the time out period to 1 second.
ALARM ACTION
The
SW-D7000U
provides extensive alarm handling capability:
On alarm activation:
"
A full-screen image of the camera in alarm will automatically appear on Monitor-B.
"
Monitor-A will automatically switch to pre-programmed quad display for a single alarm. In
addition, a different pre-programmed multi-screen display for multiple, simultaneous alarm
occurrences may be displayed.
"
The programmer can program the unit to automatically freeze the camera-in-alarm at the
instant of alarm.
"
Each alarm input can be programmed by the programmer to activate either one or both of
the Alarm Output Relays.
Simple menu tables make it quick and easy for the programmer to select the desired alarm action for
each camera.
Alarm Action Set-Up:
The programmer can program the ‘camera in alarm’ and three ‘associated cameras’ which will be
most useful to view with the alarm camera, using the ALARM ACTION section of the ALARMS sub-
menu. This allows the programmer to program any 4 camera numbers. The first camera number
will define the camera in alarm on Monitor-A and Monitor-B.
The factory default for the camera in alarm is the camera having the same number as the alarm
input. (For example, the camera in alarm factory default for alarm input #6 will be camera #6.)
The factory defaults for associated cameras will be the camera before the camera in alarm, plus the
two cameras
after
the camera in alarm.
Example:
The default for associated cameras for camera #6 will be 5, 7 and 8, while the default for associated
cameras for camera #1 will be 16, 2, 3. The three automatic custom alarm screens are as follows,
depending on the number of active alarms:
Displays for more than 3 simultaneous alarms:
If more than 3 alarms are active at the same time, the
SW-D7000U
will automatically select a display
format which is able to show all the cameras in alarm. Associated cameras will not be selected for
display, and alarms will not be frozen. This will be a 9-way display. As each new alarm is received,
the unit will automatically adjust the display.
Freezing Alarms on Monitor-A in Live Mode
The programmer can choose to have the camera in alarm frozen at the instant of the alarm. Use the
YES/NO selection under FRZ in the ALARM ACTION section of the ALARMS sub-menu to select this
option. The factory default for all alarm inputs is that the camera-in-alarm will be frozen when an
alarm input is received.