Means for disconnection must be incorporated in
the fixed wiring in accordance with the wiring rules.
-
For additional protection, the installation of a
residual current device (RCD) having a rated
residual operating current not exceeding 30 mA is
advisable in the electrical circuit supplying the
bathroom. Ask your installer for advice.
-
When the hairdryer is used in a bathroom, unplug it
after use since the proximity of water presents a
hazard even when the hairdryer is switched off.
-
Never block the air grilles
TECHNICAL CHARACTERISTICS
Supply voltage : 230V (220-240V) 50/60Hz
Power : 1600W
Air flow : 65 and 95 m3/h
IP21 depends on the installation
Electrical insulation : Class II
– no need earthing
Depending on the model, the wall mounting may also carry a shaver
socket 230V or 115V/230V
GENERAL POINTS
This hair dryer, specially designed for hotel use, is equipped with a
rocker switch in the handle which prevents its use except when held in
the hand. A soft pressure on the handle is needed to switch on the hair
dryer. It has six operating levels.
INSTALLATION IN A BATHROOM
Means for disconnection must be incorporated in the fixed wiring in
accordance with the wiring rules.
Ensure that your installation has a multipole separation with an
aperture of at least 3 mm.
Installation in a bathroom is permitted in area 3, it means out of reach
of a person using a bath or a shower,
on two conditions
:
1- The whole electrical circuit for the bathroom, in accordance with
standard NFC15-100 (C
EI 364…) must be protected by a residual