104
JVL Industri Elektronik A/S - User Manual - Ethernet for MAC and MIS motors
Configuration with explicit messages
Then configure the maximum motor torque to be used.
The motor can reach a peak torque of 300% the rated value. This value corresponds to
1023 in the register. We need 25% so we write 255 = 0x000000FF to instance 7
(T_SOLL).
And finally we send the command that saves the settings permanently in flash. This is ba-
sically a matter of writing the “save in flash” command to the command register 211 in
the motor. The command is 2 and the instance is 211 = 0xD3. Value = 0x00000002.
Now the motor saves the setting and resets.
It is required to toggle the 24V power in order to do a internal synchronization.
TT3020GB
TT3021GB
Summary of Contents for MAC00-EC4
Page 2: ......
Page 14: ...14 JVL Industri Elektronik A S User Manual Ethernet expansion modules for MAC motors ...
Page 32: ...32 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 78: ...78 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 136: ...136 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 176: ...176 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 177: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 177 8 Sercos ...
Page 224: ...224 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 241: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 241 ...
Page 252: ...252 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 256: ...256 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 257: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 257 12 Appendix ...