JVL Industri Elektronik A/S - User Manual - Ethernet for MAC and MIS motors
293
Reg Name
Size Access Range
Default Unit
Description
MacTalk
name
22
FLWERRMAX
32bit R/W
(
‐
2
31
)
‐
(2
31
‐
1)
0
Steps
The
maximum
allowed
value
in
FLWERR
before
an
error
is
triggered.
If
FLWERRMAX
=
0,
the
error
is
disabled.
Error
handling
‐
>
Follow
error
23
Reserved
(intended
for
64
‐
bit
FLWERRMAX
hi
‐
word)
24
COMMAND
32bit R/W
FastMac
commands:
0
‐
127
Other:
256
‐
0
‐
Used
to
issue
commands
to
the
motor.
0
‐
127
is
the
normal
FastMac
commands,
where
only
a
subset
is
implemented
in
SMC85/66.
Special
command
25
STATUSBITS
32bit R
‐
‐
Special
Status
bits:
Bit
0:
Reserved
Bit
1:
AutoCorrection
active
Bit
2:
In
Physical
Position
Bit
3:
At
velocity
Bit
4:
In
position
Bit
5:
Accelerating
Bit
6:
Decelerating
Bit
7:
Zero
search
done
Bit
8:
PassWord
lock
Bit
9:
Magnetic
encoder
error
Bits
10
‐
13:
Reserved
Bit
14:
Electromech.
brake
active
(Int./Ext.)
Bit
15:
Closed
loop
lead/lag
detected
Bit
16:
Closed
loop
activated
Bit
17:
Internal
encoder
calibrated
(ready
for
closed
loop)
Bit
18:
Standby
current
is
used
Bit
19:
External
memory
ok
Bit
20:
Internal
encoder
ok
Bit
21:
Ethernet
sync
activated
Bit
22:
In
target
position
Bit
23:
STO
channel
A
ok
Bit
24:
STO
channel
B
ok
Bit
25
‐
31:
Reserved
Run
Status
26
TEMP
32bit R
‐
‐
2.27
–
uses
offset
Temperature
measured
inside
the
motor.
See
the
detailed
description
for
information
on
the
value
scaling.
Temperature
28
MIN_P_IST
32bit R/W
(
‐
2
31
)
‐
(2
31
‐
1)
0
Steps
Negative
software
position
limit
Position
limit
min
29
Reserved
(intended
for
64
‐
bit
MIN_P_IST
hi
‐
word)
30
MAX_P_IST
32bit R/W
(
‐
2
31
)
‐
(2
31
‐
1)
0
Steps
Positive
software
position
limit
Position
limit
max
31
Reserved
(intended
for
64
‐
bit
MAX_P_IST
hi
‐
word)
32
ACC_EMERG
32bit R/W
1
‐
500,000
10,000
RPM/s
Acceleration
to
use
when
performing
an
emergency
stop
when
an
error
has
occurred.
Error
acceleration
33
IN_POSITION_WINDOW 32bit R/W
0
‐
(2
32
‐
1)
20000
Steps
Selects
how
close
the
internal
encoder
position
must
be
to
P_SOLL
to
set
the
InPhysical
‐
Position
status
bit
and
prevent
further
AutoCorrection.
In
position
window
34
IN_POSITION_COUNT
32bit R/W
0
‐
100
2
Counts
The
number
of
times
to
attempt
AutoCorrection.
A
value
of
zero
disables
AutoCorrection.
Max.
number
of
retries
Summary of Contents for MAC00-EC4
Page 2: ......
Page 14: ...14 JVL Industri Elektronik A S User Manual Ethernet expansion modules for MAC motors ...
Page 32: ...32 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 78: ...78 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 136: ...136 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 176: ...176 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 177: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 177 8 Sercos ...
Page 224: ...224 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 241: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 241 ...
Page 252: ...252 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 256: ...256 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 257: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 257 12 Appendix ...