5.2
Protocol specifications
5.2.1
Ethernet Powerlink communication
In an Ethernet POWERLINK network, one of the nodes, for example a PLC, is designat-
ed to function as the MN, the master in the network. All other devices operate as CNs,
slaves in the network. The MN defines the clock pulse for the synchronization of all de-
vices and manages the data communication cycle. In the course of one clock cycle within
which all nodes are addressed, the MN sends Poll Requests (PReq) to all CNs, one after
another. They reply immediately to the prompts with Poll Responses (PRes).
The following time phases exist within one cycle:
- Isochronous phase
- Asynchronous phase
- Idle phase
The MN first sends a Start of Cycle Frame (SoC) signal to all CNs to synchronize the de-
vices. Payload data exchange then proceeds in the isochronous phase. The asynchronous
phase, allows the transfer of large packets that are not time-critical, for example param-
eterisation data or transfer of IP-based protocols like TCP or UDP. The Idle phase can
be 0. It's possibly for the MN to multiplex the time slots in the isochronous phase, in or-
der to service some CN's more often than others. During system start-up the MN applies
a reduced POWERLINK cycle, without the isochronous phase, in order to configure the
CNs with SDO communication.
For further information, please refer to the Ethernet POWERLINK communication pro-
file specification “EPSG_DS_301_V-1-1-0_01.pdf”, available at the EPSG website
.
Controlled Node
Managing Node
SoC
PReq
to CN 1
PRes
from CN 1
PReq
to CN 2
PRes
from CN 2
PReq
to CN n
PRes
from CN n
Isochronous Phase
SoA
Async.
send
PRes
from MN
Powerlink cycle
Asynchronous
Phase
Id
le
P
has
e
SoC
PReq
to CN 1
PReq
to CN n
PRes
from MN
SoA
Async.
send
PRes
from CN 1
Start of Cyclic :
Sent from MN, multi-cast to all Controlled Nodes
Poll Request :
Sent from MN, uni-cast to each Controlled Node
Poll Responce :
Sent from CN, multi-cast to all nodes
Poll Responce :
Sent from MN, multi-cast to all nodes
Start of Acyclic :
Sent from MN, multi-cast to all Controlled Nodes
Async data :
Sent by any CN, invited by Managing Node
TT3035GB
Summary of Contents for MAC00-EC4
Page 2: ......
Page 14: ...14 JVL Industri Elektronik A S User Manual Ethernet expansion modules for MAC motors ...
Page 32: ...32 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 78: ...78 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 136: ...136 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 176: ...176 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 177: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 177 8 Sercos ...
Page 224: ...224 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 241: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 241 ...
Page 252: ...252 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 256: ...256 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 257: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 257 12 Appendix ...