202
JVL Industri Elektronik A/S - User Manual - Ethernet for MAC and MIS motors
Used IDN’s for setup of cyclic data with FSP Drive:
“RO”
=
Read
Only,
”RW”
=
Read
and
Writeable,
”C”
=
Map
able
to
Cyclic
data,
“T”
=
Map
able
to
real
Time
bits.
(4)
Only
available
if
drive
profile
(FSP
Drive)
selected.
8.3.7
Diagnosis (errors and warnings)
Used IDN’s in Diagnosis.
“RO”
=
Read
Only,
”RW”
=
Read
and
Writeable,
”C”
=
Map
able
to
Cyclic
data,
“T”
=
Map
able
to
real
Time
bits.
(2)
Only
available
in
MIS/MILxxxxxxESxxxxx
(MIS/MIL
stepper
motor
with
integrated
Sercos®
module).
(4)
Only
available
if
drive
profile
(FSP
Drive)
selected.
The JVL Sercos
®
module supports the standard error bits in IDN
S-0-0011
(C1D),
standard warning bits in
S-0-0012
and also some manufacturer specific error bits in IDN
S-0-0129
and some manufacturer specific warning bits in
S-0-0181
. The error bits can
be cleared with the command IDN
S-0-0099
. All message, warning and error numbers
are saved in the IDN
S-0-1303.0.x
with a time stamp, up to a maximum of 512 entrys.
8.3.7.1
Error messages (C1D)
Errors (Class 1 Diagnostics) are signaled by the slave by setting bit 13 in the status word
(
S-0-0135
), and the course of the error is then shown in the parameter
S-0-0011
or
S-
0-0129
. And in IDN
S-0-0390
is the error number and in
S-0-0095
the corresponding
error description. If an error is indicated in
S-0-0129
then also bit 15 of
S-0-0011
is set.
The error bits can be cleared with the command IDN
S-0-0099
.
IDN
Description
Default Units
Attributes
S-0-0187
(4)
IDN-list of configurable data as producer
(AT data =
Slave to Master)
RO
S-0-0188
(4)
IDN-list of configurable data as consumer (MDT
data = Master to Slave)
RO
S-0-1050.0.6
Mapped cyclic consumer data (AT data = cyclic data
from motor to PLC)
RW
S-0-1050.1.6
Mapped cyclic producer data (MDT data = Cyclic
data from PLC to motor)
RW
IDN
Description
Default
Units
Attributes
S-0-0011
(4)
Class 1 diagnostic (C1D) – Error flags
-
-
RO, C
S-0-0012
(4)
Class 2 diagnostic (C2D) – Warning flags
-
-
RO, C
S-0-0013
(4)
Class 3 diagnostic (C3D) – Status flags
-
-
RO
S-0-0095
Diagnostic message
-
-
RO
S-0-0099
Reset class 1 diagnostic procedure command
(Clear errors)
-
-
RW
S-0-0129
(4)
Manufacturer class 1 diagnostic (MC1D) – Error
flags
-
-
RO
S-0-0181
(2,4)
Manufacturer class 2 diagnostic (MC2D) – Warning
flags
-
-
RO
S-0-0390
Diagnostic message number
-
-
RO
S-0-1303.0.2
Diagnosis trace control
-
-
RW
S-0-1303.0.3
Diagnosis trace state
-
-
RO
S-0-1303.0.10 Diagnosis trace buffer 1
-
-
RO
S-0-1303.0.11 Diagnosis trace buffer 2
-
-
RO
Summary of Contents for MAC00-EC4
Page 2: ......
Page 14: ...14 JVL Industri Elektronik A S User Manual Ethernet expansion modules for MAC motors ...
Page 32: ...32 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 78: ...78 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 136: ...136 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 176: ...176 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 177: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 177 8 Sercos ...
Page 224: ...224 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 241: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 241 ...
Page 252: ...252 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 256: ...256 JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors ...
Page 257: ...JVL Industri Elektronik A S User Manual Ethernet for MAC and MIS motors 257 12 Appendix ...