background image

12

A    Specifications 

Complies with PXI specifications and accepts modules compliant with CompactPCI, PICMG 

2.0 specifications. 

Electrical 

AC Power Supply  

•  460W + 460W hot swappable 1+1 redundant power supply 
•  Input voltage: 90-264VAC universal, full range 
•  Input frequency: 47 to 63Hz 
•  Input current per power module 

 

◦ 4ARMS for 230VAC 

 

◦ 8ARMS for 115VAC 

•  Inrush current per power module

 

◦   75ARMS for 230VAC 

 

◦ 55ARMS for 115VAC 

•  Built-in active power factor correction 
•  Output 

 

◦ Maximum usable power: 460 W+460 W 

 

◦ Output characteristics per module  

VDC 

Minimum

Maximum

Ripple and 

Noise Max 

Load 

Regulation

Line 

Regulation

+5 V 

5.0 A 

40 A 

60 mA 

±5% 

±1% 

+12 V 

2.5 A 

27 A 

100 mA 

±5% 

±1% 

-5 V 

0 A 

0.8 A 

100 mA 

±5% 

±1% 

-12 V 

0 A 

1.0 A 

100 mA 

±5% 

±1% 

+3.3 V 

1.0 A 

30 A 

60 mA 

±5% 

±1% 

+5Vsb 

0.1 A 

2 A 

60 mA 

±5% 

±1% 

 

◦ +5V and +3.3V maximum total output: 50A 

•  International standards of power supply 

 

◦ Safety: UL 1950/CSA 22.2 No. 950, TUV IEC 950 

 

◦ EMI: FCC Class B, CISPR22 Class B  

•  Efficiency: Typically 65% at full load 
•  Power supply dimension: 195 (D) mm x 356 (W) mm x 99 (H) mm

Over-Load protection 

Over Current Protection 

Over Voltage Protection 

+5V 

44A-60A 

5.7V-6.5V 

+3.3V 

33A-45A 

3.9V-4.3V 

+12V 

27.5A-37.5A 

13.6V-15V 

Summary of Contents for PXI-62700

Page 1: ...PXI 62700 3U 18 Slot PXI Chassis and Accessories User s Manual Manual Revision 1 00 Revision Date Jul 15 2016...

Page 2: ...equire any service or assistance SHANGHAI JYTEK Co Ltd Web site http www jytek com Address 201203 300 Fang Chun Rd Zhangjiang Hi Tech Park Pudong New Area Shanghai 201203 China Tel 86 21 5047 5899 Fax...

Page 3: ...ts 6 3 5 Local Bus 6 3 6 Trigger Bus 6 3 7 System Reference Clock 9 4 Troubleshooting and Preventative Maintenance 10 4 1 Troubleshooting the PXI 62700 10 4 2 Cleaning 10 4 2 1 Interior Cleaning 10 4...

Page 4: ...III Warranty Policy 26...

Page 5: ...IV List of Tables Table 4 1 Troubleshooting 10...

Page 6: ...the PXI 62700 chassis 2 Figure 1 2 Rear View of the PXI 62700 chassis 3 Figure 3 1 PXI Local Bus and Star Trigger Routing 8 Figure A 1 PXI 62700 Dimensions 14 Figure B 1 cBX 3018L front view Drawing 1...

Page 7: ...R Mean Time To Repair 1 1 Unpacking Checklist Check the shipping carton for any damages If the shipping carton and contents are damaged notify the dealer for a replacement Retain the shipping carton a...

Page 8: ...Two PXI to PXI bridges Figure 1 1 1 2 show some of the feature and components of the PXI 62700 chassis Figure 1 1 shows the front view of the PXI 62700 Figure 12 shows the rear view of the PXI 62700 F...

Page 9: ...dard backplanes we provide more options for OEM customers as long as the request backplane is PXI or 3U CompactPCI form factor compliant with 21 slot width limitation For example application may requi...

Page 10: ...r injector handle to fully inject the card into the chassis Secure the screws on the module s front panel Step 4 Install peripheral modules if any Step 5 Press the power switch on the front panel to p...

Page 11: ...is power RST When the alarm buzzer beeps and the power LED extinguishes you can push power RST button to stop beeping and refer to Chapter 4 5 to hot swap the power supply unit 2 4 Grounding on the M...

Page 12: ...allow the controller to expand to the left to prevent the controller from using up peripheral slots 3 3 Star Trigger Slot The Star Trigger ST slot is Slot 2 This slot has a dedicated trigger line bet...

Page 13: ...ferent PXI peripheral modules or use one module to control carefully timed sequences of operations performed on other modules in the system Modules can pass triggers to one another through trigger bus...

Page 14: ...8 Figure 3 1 PXI Local Bus and Star Trigger Routing...

Page 15: ...heral slot Users can use this common reference clock signal to synchronize multiple modules in a measurement or control system or drive PXI_CLK10 from an external source through the PXI_CLK10_IN pin o...

Page 16: ...the fan hot swap replacement The Power Buzzer is beeping Check if both power supplies have power cord on it If either one of the power supply failed please refer to Chapter 4 5 for the power supply ho...

Page 17: ...of fans 3 Pull out the defective fan 4 Replace with a new fan 5 Cover back the fans panel cover 4 5 Power Supply Unit Hot Swap Replacement For the PXI 62700 chassis there are four Green LED indicator...

Page 18: ...ble power 460 W 460 W Output characteristics per module VDC Minimum Maximum Ripple and Noise Max Load Regulation Line Regulation 5 V 5 0 A 40 A 60 mA 5 1 12 V 2 5 A 27 A 100 mA 5 1 5 V 0 A 0 8 A 100 m...

Page 19: ...ormal condition Flashes if alarm occurs Alarm Buzzer Beep if any alarm occurs Alarm RST button Reset the alarm monitor system Cooling Fans Front access hot swappable fan trays Five 31CFM fans trays at...

Page 20: ...o 70 C Relative humidity 5 to 95 non condensing Backplane Backplane bare board material UL 94V 0 rated Backplane connectors Conforms to IEC 917 and IEC 1076 4 101 UL 94V 0 rated Number of PXI CompactP...

Page 21: ...and Vibration Shock 15G peak to peak 11ms duration non operation Random Vibration Operating 5 to 500Hz 0 5GRMS each axis Non operating 5 to 500Hz 1 88GRMS each axis Safety and EMC EMI Compliance Safet...

Page 22: ...f the backplanes and Mechanical Drawing 1 2 3 4 5 6 9 sys 3 4 5 7 6 8 1 2 8 7 1 0 1 1 1 2 1 7 1 3 1 6 1 5 1 4 9 11 12 13 14 15 16 17 18 10 Figure B 1 cBX 3018L front view Drawing R 1 7 6 5 4 3 2 sys 1...

Page 23: ...ridge Board Third PCI Bus Slot 13 Third PCI Bus Slot 14 Third PCI Bus Slot 15 Third PCI Bus Slot 16 Third PCI Bus Slot 17 Third PCI Bus Slot 18 64 bit PCI 64 bit PCI 64 bit PCI PXI Trigger bus Group 1...

Page 24: ...GND 7 GND AD 30 AD 29 AD 28 GND AD 27 GND 6 GND REQ 1 GND 3 3V CLK 1 AD 31 GND 5 GND BRSVP1A5 BRSVP1B5 PCIRST GND GNT 1 GND 4 GND IPMB_PWR GND V I O INTP INTS GND 3 GND INTA 1 INTB 1 INTC 1 5V INTD 1...

Page 25: ...V I O STOP LOCK GND 15 GND 3 3V FRAME IRDY GND TRDY GND 12 14 Key 11 GND AD 18 AD 17 AD 16 GND C BE 2 GND 10 GND AD 21 GND 3 3V AD 20 AD 19 GND 9 GND C BE 3 IDSEL 1 AD 23 GND AD 22 GND 8 GND AD 26 GN...

Page 26: ...al Slot Slot 3 6 P1 Pin Assignment Pin Z A B C D E F 25 GND 5V REQ64 ENUM 3 3V 5V GND 24 GND AD 1 5V V I O AD 0 ACK64 GND 23 GND 3 3V AD 4 AD 3 5V AD 2 GND 22 GND AD 7 GND 3 3V AD 6 AD 5 GND 21 GND 3...

Page 27: ...GND 5 GND C BE 5 GND V I O C BE 4 PAR64 GND 4 GND V I O PXI_BRSVB4 C BE 7 GND C BE 6 GND 3 GND PXI_LBR7 GND PXI_LBR8 PXI_LBR9 PXI_LBR10 GND 2 GND PXI_LBR11 PXI_LBR12 N C SYS PXI_LBL7 PXI_LBL8 GND 1 GN...

Page 28: ...XI_STAR P2 D17 Slot 2 Star Trigger Slot PXI_STAR0 PXI_STAR12 Slot 3 PXI_STAR0 Slot 4 PXI_STAR1 Slot 5 PXI_STAR2 Slot 6 PXI_STAR3 Slot 7 PXI_STAR4 Slot 8 PXI_STAR5 Slot 9 PXI_STAR6 Slot 10 PXI_STAR7 Sl...

Page 29: ...t signal J6 Pin Signal Name 1 INH 2 GND J8 RST System reset signal J8 Pin Signal Name 1 RST 2 GND J9 FAL Power supply fail input J9 Pin Signal Name 1 FAL 2 GND J5 Connector for LED power status J5 Nam...

Page 30: ...24 JP1 10MHz Reference Clock Pin Name 1 2 default Internal 10MHz system clock PXI_CLK10 2 3 External clock through the PXI_CLK10_IN on star trigger slot...

Page 31: ...transient overvoltage 8 Make sure the voltage of the power source when connect the equipment to the power outlet 9 All cautions and warnings on the equipment should be noted 10 Please keep this equipm...

Page 32: ...rranty will not cover repair costs due to Damage caused by not following instructions Damage caused by carelessness on the users part during product transportation Damage caused by fire earthquakes fl...

Reviews: