3    System Management & Configuration

The  PXIe-62780  chassis  provides  advanced  system  monitoring  and  control.  Chassis  

conditions,  including  internal  temperature, fan  speed, and DC voltage can all be monitored 

on the system controller or remote PC. 
The PXIe-62780 provides software configurable trigger bus bridges, whereby the user can 

set the status of each trigger bus line as shown in Figure 1-13. The PXIe-62780 backplane 

can also be configured between 4-link x 4 lanes or 2-link x 8 lanes by the configurable PCIe 

switch fabric.
Communication with the chassis monitoring control unit is available using an embedded 

controller, such as the JYTEK PXIe-63975, to access the SMBus located on the system slot 

(1st slot), or, alternatively, using a remote PC to communicate via the RS232 serial port 

(D-SUB9 connector on the rear panel). 
Please note that the RS-232 serial port can only monitor chassis status, but does not provide 

the capability to change the trigger bus bridges and PCIe switch fabric settings. Function 

comparison between the SMBus interface and RS-232 serial port is as follows.

Function

SMBus

RS-232 Serial Port

Chassis status monitoring

Yes

Yes

Alarm threshold setting

Yes

Yes

Trigger Bus setting

Yes

No

PXIe link setting

Yes

No

Table  3-1: Supported Function Comparison Between SMBus Interface and RS-232 Serial 

Port

3�1    Installing the Monitor Utility

Download JYTEK PXI Platform Services driver from http://www.jytek.com
To install the monitoring utility:

1. Open PXI Platform Services drive folder which downloads from JYTEK website.
2. Double-click the JYTEK PXI Platform Services Setup.exe file to begin installation.

The PXIe-62780 Chassis Remote Monitoring utility is only compatible with JYTEK PXI 

Express controllers such as the PXIe-63975. 3rd party embedded controllers require 

dedicate programming to enable system monitoring, as listed in the PXIe-62780 

Function Library Reference documentation, or use of a remote PC to monitor the 

PXIe-62780 via RS-232 serial port.

 

Summary of Contents for PXIe-62780

Page 1: ...PXIe 62780 18 slot PXI Express Chassis User s Manual Manual Rev 1 00 Revision Date Jul 15 2016...

Page 2: ...201203 China Tel 86 21 5047 5899 Fax 86 21 5047 5899 Email service jytek com Additional information aids and tips that help users perform tasks Information to prevent minor physical injury component d...

Page 3: ...2 3 2 Installing Peripheral Modules 18 2 4 Rack Mounting 20 2 4 1 Powering Up the System 21 3 System Management Configuration 22 3 1 Installing the Monitor Utility 22 3 2 Monitoring the PXIe 62780 23...

Page 4: ...Rear Panel Legend 8 Table 1 4 PXI Star Trigger Line Assignment 11 Table 1 5 PXIe 62780 Reference Clock Priority 14 Table 2 1 Rack Mount Assembly Legend 20 Table 3 1 Supported Function Comparison Betwe...

Page 5: ...8 PXIe 62780 Backplane 9 Figure 1 9 Temperature Sensors on Backplane 9 Figure 1 10 Star Trigger Routing 10 Figure 1 11 3U Hybrid Slot Compatible PXI 1 Peripheral Module 12 Figure 1 12 3U PXI Express P...

Page 6: ...an innovative cooling scheme providing superior heat dissipation Three 185 9CFM fans in the rear section of the chassis draw cool air from apertures on the bottom and front of the chassis over the PXI...

Page 7: ...Maximum Load Regulation Maximum Ripple Noise 5V 29 0 A 3 50 mV 12V 45 0 A 3 50 mV 3 3V 60 0 A 3 50 mV 12V 2 5 A 3 50 mV 10 MHz System Reference Clock 10 MHz REF Maximum clock skew between slots 300 ps...

Page 8: ...oncondensing Functional shock 30 G half sine 11 ms pulse duration Random Vibration Operating 5 to 500 Hz 0 3 Grms 3 axes Nonoperating 5 to 500 Hz 2 46 Grms 3 axes Sound Pressure Level at operator posi...

Page 9: ...4 1 3 Schematics All dimensions are shown in mm millimeters Figure 1 1 Front View 465 3 Figure 1 2 Right Side View...

Page 10: ...5 Figure 1 3 Left Side View Figure 1 4 Rear View...

Page 11: ...ont Panel Legend Status Temperature Amber Fan Green Power Blue On Lit N A Fans operating normally DC voltage supply is normal Off Temperature is normal Chassis is powered down Chassis is powered down...

Page 12: ...puter using a standard D sub9 cable with pin assignments shown in Figure 1 7 Note The remote monitor port is Rx Tx Tx Rx crossed such that a RS 232 cable with Rx Rx Tx Tx connection must be used F Inh...

Page 13: ...In the HIGH position fans operate at maximum speed and in AUTO the fans run based on the monitored chassis temperature I Universal Power Inlet Accepts IEC 60320 1 C19 power outletequipped connection J...

Page 14: ...1 4 3 Backplane Figure 1 8 PXIe 62780 Backplane T1 T2 T3 T4 T5 T6 T7 T8 Figure 1 9 Temperature Sensors on Backplane For details of chassis temperature detection please see Chassis Temperature on page2...

Page 15: ...ts and PXI Express Peripheral Slots comply with the default pin assignments as defined in PXI 5 PXI Express hardware specification Rev 1 0 PXI Express System Controller Slot The System Controller slot...

Page 16: ...I Express x4 lanes peripheral slot if star trigger functionality is not required PXI Express Hybrid Peripheral Slots 10 PXI Express hybrid peripheral slots are provided in the PXIe 62780 all connected...

Page 17: ...ripheral Module Figure 1 12 3U PXI Express Peripheral Module Local Bus The local bus on a PXI backplane is a daisy chained bus that connects each peripheral slot with adjacent peripheral slots to the...

Page 18: ...taining 8 trigger lines connecting all slots on the same segment providing inter module synchronization PXI and PXI Express modules can exchange trigger or clock signals through the trigger bus allowi...

Page 19: ...ce the external 10MHz clock input can override the onboard 10MHz clock source a phase lock loop PLL circuit on the backplane synchronizes the PXIe_ CLK100 and external 10MHz clock The PXIe 62780 PXI c...

Page 20: ...ipping materials and carton in case you want to ship or store the product in the future Do not install or apply power to equipment that is damaged or missing components Retain the shipping carton and...

Page 21: ...on 2 3 1 Installing the System Controller The PXIe 62780 incorporates a system controller slot supporting a PXI Express system controller of up to 4 slot width 1 Ensure the CPU memory module s and sto...

Page 22: ...s with the cardguides and carefully slide the module into the chassis 5 Lift the latch until the module is securely seated in the chassis backplane 6 Fasten the screws on the module front panel and co...

Page 23: ...ding a system timing module 1 Select an available peripheral slot 2 to 18 2 Depress the peripheral module s latch and align the module s top and bottom edges with the card guides 3 Carefully slide the...

Page 24: ...the module s front panel 6 Repeat steps 1 to 5 to install additional PXI or PXIe peripheral modules To improve efficiency of heat dissipation after installing all PXI modules please install filler pl...

Page 25: ...e 2 1 Rack Mount Assembly A Carrying Handle B 4 Rubber Feet only 2 shown C Mounting Brackets Table 2 1 Rack Mount Assembly Legend 1 Remove carrying handle from the right side 2 Remove the four rubber...

Page 26: ...t voltage selection 1 Connect one end of the supplied power cord to thepower inlet located at the rear side of the chassis 2 Plug the other end of the AC power cord to a properly grounded wall socket...

Page 27: ...tatus but does not provide the capability to change the trigger bus bridges and PCIe switch fabric settings Function comparison between the SMBus interface and RS 232 serial port is as follows Functio...

Page 28: ...Control and Chassis Status Figure 3 1 PXIe 62780 Chassis Remote Mon Utility 3 2 1 Connect Control Interface Selects the communication interface between PXIe 62780 and utility Select Set to apply SMBus...

Page 29: ...s available while Interface is set to RS232 Baud rate for RS232 is set to 9600 automatically for PXIe 62780 Chassis Status Log With the Chassis Status Log function monitored data can be recorded Selec...

Page 30: ...Alarm Threshold Setting Provides operational and threshold settings for the PXIe 62780 including trigger bus PXIe link target temperature and fan mode and threshold settings for DC voltage temperature...

Page 31: ...sed on the measured temperature Target Temp indicates the temperature at which fans run at 100 Using the default 50 C as an example fans run at 40 when all temperature readings are less than 25 C and...

Page 32: ...n at full speed Selection of Auto or Full values and selecting Set directly changes cooling fan mode Alarm Threshold Displays Active alarm threshold settings including DC voltage temperature and fan s...

Page 33: ...If the system fails to start when all installation conditions are met remove all installed peripheral modules and try again If the system starts normally install one peripheral module at a time follow...

Page 34: ...of the chassis for superior portability and balance The PXIe 62780 weights 11 9 kg 26 2 lb Please be careful when moving the chassis to avoid any possible injury A 3 2 Cleaning the Exterior Make sure...

Page 35: ...power source settings Always install and operate equipment near an easily accessible electrical socket outlet Secure the power cord do not place any object on over the power cord Only install attach a...

Reviews: