KNX Gateway for IR _V1.2
KNX Gateway for IR,Flush mounted,2-Fold
BTIRF-02/00.2
KNX Gateway for IR,Ceiling
BTIRC-01/00.2
KNX/EIB Home and Building Control System
User manual
Page 1: ...KNX Gateway for IR _V1 2 KNX Gateway for IR Flush mounted 2 Fold BTIRF 02 00 2 KNX Gateway for IR Ceiling BTIRC 01 00 2 KNX EIB Home and Building Control System User manual...
Page 2: ...es away from strong magnetic field high temperature wet environment 2 Do not fall the device to the ground or make them get hard impact 3 Do not use wet cloth or volatile reagent to wipe the device 4...
Page 3: ...DCA Note 9 5 2 Parameter window General setting 10 5 3 Parameter window Channel x x 1 2 12 5 3 1 Parameter window Universal IR control setting 12 5 3 2 Parameter window Air condition control setting 1...
Page 4: ...or KNX Gateway for IR is used for auxiliary IR code to learn test configure and download the IR code to the device KNX bus can control IR device after ETS configuration Note KNX Gateway for IR configu...
Page 5: ...tion function up to 10A can be associated to the transmitting channel Only KNX Gateway for IR Flush mounted supports the function Support up to 16 sequence controls each sequence supports up to 4 IR c...
Page 6: ...tion range 50mA 10A Current detection accuracy 50mA 500mA 20mA 500mA 10A 5 Output Channel 2 independent channels Max Transmitting distance 2m IR wavelength 940nm IR emission receiving angle 45 Connect...
Page 7: ...Operation voltage 21 30V DC via the KNX bus Bus current 8mA 24V 7mA 30V Bus consumption 210mW Dynamic current 14mA 24V 12mA 30V Output IR wavelength 940nm Radius distance 3m Installation Height 4m Con...
Page 8: ...EIB KNX Gateway for IR 5 Chapter 3 Dimension and Connection Diagram 3 1 Dimension diagram Fig 3 1 1 KNX Gateway for IR Flush mounted 2 Fold BTIRF 02 00 2 Fig 3 1 2 KNX Gateway for IR Ceiling BTIRC 01...
Page 9: ...gramming LED Programming button KNX bus connection terminal Device load connection terminals if require current detection Connectors for Infrared emitter cable Fig 3 2 2 KNX Gateway for IR Ceiling BTI...
Page 10: ...ontrol and Channel 2 can be used for Air condition control Universal IR control Each channel up to support 30 IR code configurations is used for universal control such as Fan TV DVD and etc You can se...
Page 11: ...sensor turn off Air condition after delay a time when receives the room unoccupied command to save energy Sequence sending function Up to support 16 sequence controls Each sequence supports 1 bit or...
Page 12: ...mounted are mainly different in without current detection function 5 1 Parameter window DCA Note Fig 5 1 DCA Note parameter window A noting message Remote IR code learning and downloading must use IR...
Page 13: ...on will send a telegram according to the set period time with logic 1 to the bus Options 0 240s 0 inactive As to reduce the bus load as much as possible the maximum time interval should be selected ac...
Page 14: ...rameter Monitoring period of current ON OFF 0 255 0 inactive min This parameter is visible when current detection status is selected as External Set the monitoring period of external current switch st...
Page 15: ...nt window after selected Parameter Current detection function This parameter is for setting whether to enable current detection function display the relevant window after selected 5 3 Parameter window...
Page 16: ...e object datatype for triggering the IR code emit Options 1bit On Off 1byte 0 255 Parameter Trigger value This parameter is for setting the received value when IR code emission is triggered The value...
Page 17: ...se not Both 1 and 0 both emit when the current status is On or Off Parameter Status response This parameter is for setting whether to reply a status value to the bus after the device emitting IR code...
Page 18: ...KNX EIB KNX Gateway for IR 15 5 3 2 Parameter window Air condition control setting Fig 5 3 2 1 Air condition control setting parameter window...
Page 19: ...Parameter Description max 30char This parameter is for setting the custom description of Air condition and the description of corresponding object name of Air condition will also change Up to 30 char...
Page 20: ...ack according to the configuration of the initial status The following parameters are for setting the initial status when power on Air condition Parameter Temperature This parameter is for setting the...
Page 21: ...for setting the adjustable range for limiting the temperature setpoint value The minimum value must be less than the maximum value If the setpoint value exceeds the limited range output according to...
Page 22: ...s parameter is visible when the previous parameter enabled Set the delay time for turning off Air condition when receive a command of opening window from sensor to save energy Options 0 255 Parameter...
Page 23: ...dition mode When enabled relevant settings are visible Parameter Control value for heating cooling dehumidification fan auto mode 0 255 These parameters are visible when modes enabled Set to switch to...
Page 24: ...odes settings are similar Fig 5 3 2 4 Auto Fan speed Wind parameter window Parameter 1 Assign IR code NO 1 300 This parameter is for setting the IR code number corresponding to the combination functio...
Page 25: ...IR code but the control function is indicated in the title of the parameter window view on the left side of parameter configuration window So that we need find IR code number in the IR code library ac...
Page 26: ...KNX EIB KNX Gateway for IR 23 5 4 Parameter window Sequence mode setting Fig 5 4 1 Sequence mode setting parameter window Fig 5 4 2 Sequence combination 1 parameter window...
Page 27: ...wing the forth is setting a timing Parameter Description max 30char This parameter is for setting the custom description of sequence and the description of corresponding object name of sequence will a...
Page 28: ...e emission IR coed of command x which is configured by configuration software tool or DCA Options 1 300 Parameter Emitting channel This parameter is for setting the emission channel connected with com...
Page 29: ...setting the object datatype of current detection value Options Value in mA DPT 7 012 Float Value in mA DPT 9 021 Value in mA DPT 7 012 the unit of output current value is mA integer data Float Value...
Page 30: ...A This parameter is for setting the current threshold for power on The device status is On when the current is greater than or equal to the value Options 100 2000 Parameter Hysteresis value 0 50 mA Th...
Page 31: ...cation object W represents the value of the communication object can be rewritten by the bus R represents the value of the communication object can be read through the bus T stands for communication o...
Page 32: ...es changes with the parameter Description max 30 char If description is empty display IR control x by default such as CH1 IR control 1 Input Below is the same 19 IR Response value CH1 IR control 1 Sta...
Page 33: ...m value is 17 decimal number 80 Control mode CH1 AC Input 1byte C W U 20 105 HVAC control mode This communication object is used to control each mode of Air condition via bus 81 Fan speed CH1 AC Input...
Page 34: ...ck current fan speed status of Air condition to bus 89 Wind swing 1 stop 0 CH1 AC Status 1bit C R T 1 017 trigger The communication object is used to feedback wind swing status of Air condition to bus...
Page 35: ...is visible when channel 1 is connected with external current detection Used to receive the current status that the current detection device detects from bus On Off 165 CH1 External error report Curren...